An experimental study is carried out for enhancement of falling film evaporation heat transfer of pure water and water/salt mixtures on horizontal smooth tube and two kinds of structured tube bundles under atmospheric pressure. The experimental results show that the low-cost roll-worked tube can greatly enhance the evaporation heat transfer performance of the falling film, and make it comparable to that of expensive commercial enhanced tubes such as GEWA-T tubes, TE tubes and HF tubes, even at low and moderate heat flux levels. The average evaporation heat transfer coefficients for the roll-worked tube bundle are basically independent from the parameters tested such as flow and heating conditions, salt-concentrations, as well as geometries of the tube bundles. The present experimental data result in a constant heat transfer coefficient; α≈ 20 kW/m{sup}2 K, in the convective heat transfer range of the heat fluxes <10{sup}5 W/m{sup}2.
机译:为了提高纯水和水/盐混合物在大气压下在水平光滑管和两种结构化管束上的降膜蒸发传热而进行的实验研究。实验结果表明,低成本的轧制管可以大大提高降膜的蒸发传热性能,使其可与昂贵的商用增强管如GEWA-T管,TE管和HF管相媲美,即使在中等和中等的热通量水平下。轧制管束的平均蒸发传热系数基本上与所测试的参数无关,例如流量和加热条件,盐浓度以及管束的几何形状。目前的实验数据导致了恒定的传热系数。在热通量<10 {sup} 5 W / m {sup} 2的对流传热范围内,α≈20kW / m {sup} 2K。