首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Effect of fin types of outdoor fan-supplied finned-tube heat exchanger on periodic frosting and defrosting performance of a residential air-source heat pump
【24h】

Effect of fin types of outdoor fan-supplied finned-tube heat exchanger on periodic frosting and defrosting performance of a residential air-source heat pump

机译:室外风扇式翅片管换热器的翅片类型对住宅空气源热泵定期除霜和除霜性能的影响

获取原文
获取原文并翻译 | 示例
       

摘要

The effect of fin types - flat, wavy and louver fins - of outdoor fan-supplied heat exchanger on the periodic frosting and defrosting performance of a residential air-source heat pump was experimentally compared. Six consecutive frosting/defrosting cycles were performed for each fin type, and the frosting/defrosting durations were almost equal, about 46.6 min and 3.9 min for each fin type, due to the same defrosting control schemes. The time-average values during the third, fourth and fifth frosting/defrosting cycles were used to compare the overall frosting/defrosting performance among three fin types, and the real-time data during the fourth cycle were analyzed to compare their dynamic characteristics. The experimental results showed the flat fin had the best thermal performance of the air-source heat pump, followed by wavy and louver fins. The time-average heating capacity, COP and input power for flat fin during frosting cycle were more by 17.1%, 9.0% and 7.6%, respectively than those for louver fin. The frosting curves for flat fin increased slightly and then decreased gradually, while the curves for wavy and louver fin types increased slightly at first, then decreased rapidly and gradually at last. Meanwhile, the curves for louver fin decreased considerably earlier than those for wavy fin. The initial increases of the frosting curves were ascribed to that the positive frost effect of increased surface roughness surpassed both the negative frost effects of increased frost layer thermal resistance and reduced fan-supplied airflow rate due to frost blockage. The frosting curves for wavy and louver fin types decreased rapidly because the outdoor axial fan experienced the stall zone caused by more frost accumulation and greater air pressure drop, and decreased slightly at last after the stall zone was went through. The frosting curves for flat fin decreased always slightly because the outdoor axial fan did not experience the stall zone during the frosting duration of 46.6 min. The frosted finned-tube heat exchanger and fan characteristic should be coupled together for the optimal design.
机译:实验比较了室外风扇提供的换热器的翅片类型(扁平,波浪形和百叶窗式翅片)对住宅空气源热泵的定期除霜和除霜性能的影响。由于相同的除霜控制方案,每种翅片进行了六个连续的除霜/除霜循环,并且每种除霜片的除霜/除霜持续时间几乎相等,分别为46.6分钟和3.9分钟。第三,第四和第五次结霜/除霜周期中的时间平均值用于比较三种散热片类型的整体结霜/除霜性能,并分析第四周期中的实时数据以比较其动态特性。实验结果表明,扁平翅片具有空气源热泵的最佳热性能,其次是波浪形和百叶窗式翅片。结霜期间,平翅片的平均时间加热能力,COP和输入功率分别比百叶窗翅片的平均时间高17.1%,9.0%和7.6%。扁平鳍的结霜曲线略有增加,然后逐渐下降,而波浪形和百叶窗式的结霜曲线则先略有增加,然后迅速并最终逐渐减少。同时,百叶窗翅片的曲线比波浪状翅片的曲线下降得早。结霜曲线的最初增加归因于表面粗糙度增加的正霜作用超过了因霜冻阻塞而增加的霜层热阻和减少的风扇供气流量的负霜作用。波浪形和百叶窗式翅片的结霜曲线迅速下降,因为室外轴流风扇经历了由于更多的霜冻积累和更大的气压降而导致的失速区,并且在失速区通过后最终略有下降。扁平散热片的结霜曲线总是略有下降,因为室外轴流风扇在46.6分钟的结霜期间没有经历失速区。磨砂翅片管换热器和风扇特性应结合在一起以实现最佳设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com