To obtain dose distributions more physically representative to the patient anatomy in brachytherapy, calculation algorithms that can account for heterogeneity are required. The current standard AAPM Task Group No 43 (TG-43) dose calculation formalism has some clinically relevant dosimetric limitations. Lack of tissue heterogeneity and scattered dose corrections are the major weaknesses of the TG-43 formalism and could lead to systematic dose errors in target volumes and organs at risk. Over the last decade, model-based dose calculation algorithms (MBDCAs) have been clinically offered as complementary algorithms beyond the TG43 formalism for high dose rate (HDR) brachytherapy treatment planning. These algorithms provide enhanced dose calculation accuracy by using the information in the patient's computed tomography images, which allows modeling the patient's geometry, material compositions, and the treatment applicator. Several researchers have investigated the implementation of MBDCAs in HDR brachytherapy for dose optimization, but moving toward using them as primary algorithms for dose calculations is still lagging. Therefore, an overview of up-to-date research is needed to familiarize clinicians with the current status of the MBDCAs for different cancers in HDR brachytherapy. In this paper, we review the MBDCAs for HDR brachytherapy from a dosimetric perspective. Treatment sites covered include breast, gynecological, lung, head and neck, esophagus, liver, prostate, and skin cancers. Moreover, we discuss the current status of implementation of MBDCAs and the challenges.
机译:更多的身体获得的剂量分布代表病人解剖近距离放射疗法,可以计算算法占异质性是必需的。现有标准AAPM任务组没有43 (TG-43)形式主义有一些临床剂量计算相关剂量测定的局限性。异质性和分散剂量修正的主要弱点TG-43形式主义可能会导致系统在目标剂量错误吗卷和器官处于危险之中。基于模型的剂量计算算法(MBDCAs)一直在临床上作为互补算法除了TG43形式为高剂量率(HDR)近距离放射疗法治疗计划。这些算法提供增强的剂量通过使用中的信息计算精度病人的ct图像,允许病人的几何建模、材料器组成,治疗。几个研究人员调查了实现在HDR MBDCAs近距离放射疗法剂量优化,但朝着使用它们作为主要的剂量计算算法仍然滞后。熟悉最新的研究是必要的临床医生MBDCAs的现状不同的癌症在HDR近距离放射疗法。这篇文章中,我们回顾一下MBDCAs HDR短距离放射治疗的剂量测定的视角。处理网站包括乳腺癌、妇科、肺癌、头颈部、食道、肝、前列腺癌和皮肤癌。讨论实施的现状MBDCAs和挑战。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号