首页> 外文期刊>Journal of instrumentation: an IOP and SISSA journal >Silicon technologies for the CLIC vertex detector
【24h】

Silicon technologies for the CLIC vertex detector

机译:Clic顶点检测器的硅技术

获取原文
获取原文并翻译 | 示例
       

摘要

CLIC is a proposed linear e~+e~- collider designed to provide particle collisions at centerof- mass energies of up to 3 TeV. Precise measurements of the properties of the top quark and the Higgs boson, as well as searches for Beyond the Standard Model physics require a highly performant CLIC detector. In particular the vertex detector must provide a single point resolution of only a few micrometers while not exceeding the envisaged material budget of around 0.2% X_0 per layer. Beam-beam interactions and beamstrahlung processes impose an additional requirement on the timestamping capabilities of the vertex detector of about 10 ns. These goals can only be met by using novel techniques in the sensor and ASIC design as well as in the detector construction. The R&D program for the CLIC vertex detector explores various technologies in order to meet these demands. The feasibility of planar sensors with a thickness of 50-150 μm, including different active edge designs, are evaluated using Timepix3 ASICs. First prototypes of the CLICpix readout ASIC, implemented in 65 nm CMOS technology and with a pixel size of 25 × 25 μm~2, have been produced and tested in particle beams. An updated version of the ASIC with a larger pixel matrix and improved precision of the time-over-threshold and time-of-arrival measurements has been submitted. Different hybridization concepts have been developed for the interconnection between the sensor and readout ASIC, ranging from small-pitch bump bonding of planar sensors to capacitive coupling of active HV-CMOS sensors. Detector simulations based on Geant 4 and TCADare compared with experimental results to assess and optimize the performance of the various designs. This contribution gives an overview of the R&D program undertaken for the CLIC vertex detector and presents performance measurements of the prototype detectors currently under investigation.
机译:CLIC是一种提出的线性E〜+E〜-碰撞器,旨在在高达3 TEV的中心能量下提供粒子碰撞。对顶部夸克和希格斯玻色子的性质的精确测量,以及搜索超出标准模型物理的搜索需要高性能的CLIC检测器。特别是,顶点检测器必须提供仅几个微米的单点分辨率,而不会超过每层约0.2%X_0的设想材料预算。梁梁的相互作用和梁的过程对约10 ns的顶点检测器的时间戳功能施加了额外的要求。这些目标只能通过在传感器和ASIC设计中以及检测器构造中使用新技术来实现。 CLIC顶点检测器的研发计划探索了各种技术,以满足这些需求。使用TimePix3 ASIC评估了厚度为50-150μm的平面传感器的可行性,包括不同的活性边缘设计。在65 nm CMOS技术中实现的Clicpix读数ASIC的第一型原型,像素大小为25×25μm〜2,已在粒子梁中生产和测试。已经提交了具有较大像素矩阵的ASIC的更新版本,并提高了阈值和到达时间的测量的精度。已经开发出不同的杂交概念,用于传感器和读取ASIC之间的互连,从平面传感器的小碰撞凸起键到活性HV-CMOS传感器的电容耦合。与实验结果相比,基于Geant 4和Tcadare的检测器仿真,以评估和优化各种设计的性能。这项贡献概述了针对CLIC顶点检测器进行的研发计划,并介绍了目前正在研究的原型检测器的性能测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号