...
首页> 外文期刊>American Journal of Sports Medicine >Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff.
【24h】

Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff.

机译:缝合材料对缝合肌腱标本生物力学行为的影响:牛肩袖的对照研究。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. Improved strength of sutures and suture anchors has resulted in the most common site of failure being the suture-tendon interface. HYPOTHESIS: The type of suture material used has a significant effect on the biomechanics of the suture-tendon interface. STUDY DESIGN: Controlled laboratory study. METHODS: Thirty-two bovine infraspinatus specimens were randomly assigned to simple suture fixation using No. 2 Fiberwire, Ultrabraid, Orthocord, or Ethibond. Each specimen was subjected to cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing. RESULTS: Cyclic testing revealed significantly greater elongation with Ultrabraid, whereas peak-to-peak displacements were lowest for Fiberwire and greatest for Orthocord. Load-to-failure testing revealed no significant differences between any suture material for ultimate tensile load. Fiberwire and Orthocord repairs had the highest stiffness. The most common failure mode during load-to-failure testing was suture breakage in Ethibond specimens and suture cutting through the tendon in the polyblend suture specimens. CONCLUSION: The type of suture material has a significant effect on the biomechanical behavior of the suture-tendon interface. CLINICAL RELEVANCE: The type of suture may influence early gap formation and ultimate healing of rotator cuff repairs.
机译:背景:尽管肩袖手术技术上的进步,修复肌腱的复发性或持续性缺陷仍继续发生。缝合线和缝合锚钉强度的提高已导致最常见的失败部位是缝合线-肌腱界面。假设:所使用的缝合线材料的类型对缝合线-肌腱界面的生物力学有重大影响。研究设计:受控实验室研究。方法:将32头牛腓肠肌标本随机分配到使用2号Fiberwire,Ultrabraid,Orthocord或Ethibond进行简单的缝合固定。对每个样品进行5到30 N的循环测试,进行30个循环,然后进行载荷-破坏测试。结果:循环测试显示,Ultrabraid的伸长率明显更高,而Fiberwire的峰峰位移最低,而Orthocord的峰位移最大。载荷到断裂的测试表明,对于最终拉伸载荷,任何缝线材料之间都没有显着差异。 Fiberwire和Orthocord修补的刚度最高。加载至破坏测试期间最常见的破坏模式是Ethibond样本中的缝合线断裂和多混合缝合样本中的穿过肌腱的缝合线。结论:缝线材料的类型对缝线-肌腱界面的生物力学行为有重要影响。临床相关性:缝合的类型可能会影响缝隙的早期形成和肩袖修复的最终愈合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号