首页> 外文期刊>Heart rhythm: the official journal of the Heart Rhythm Society >Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator
【24h】

Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator

机译:使用心电图筛选工具来确定皮下植入心脏扭曲器不纤毛的候选者

获取原文
获取原文并翻译 | 示例
           

摘要

Background An electrocardiographic (ECG) screening test has been developed to identify patients being considered for a totally subcutaneous implantable cardioverter-defibrillator (S-ICD) at risk for T-wave oversensing. Objective The purpose of this study was to determine the proportion of potential S-ICD recipients who fail the ECG screening test and to identify predictors of failure. Methods Patients who already have an ICD but are not receiving antibradycardia pacing are representative of patients who might be considered for an S-ICD. One hundred such outpatients were enrolled in the study. Surface rhythm strips were recorded along the sensing vectors of the S-ICD system and the screening template applied. Clinical and standard ECG characteristics of patients who failed the test were compared to those who passed. Results Patients had the following characteristics: 72% male, age 57 ± 16 years, body mass index 29 ± 6 kg/m2, left ventricular ejection fraction 43% ± 17%, QRS duration 109 ± 23 ms, QTc interval 447 ± 39 ms, 44% had coronary disease, and 55% had heart failure. Among the 100 patients, 8% failed the screening test. There were no differences in patient clinical characteristics and most standard ECG measurements. However, patients with T-wave inversions in standard ECG leads I, II, and aVF had a 45% chance of failing. Conclusion Eight percent of potential S-ICD patients were not eligible for the S-ICD after failing the screening test designed to identify patients susceptible to T-wave oversensing. Patients with T-wave inversions in leads I, II, and aVF on a standard ECG were 23 times more likely to fail. More work is needed in S-ICD sensing algorithms to increase patient eligibility for the S-ICD.
机译:背景已经开发了心电图(ECG)筛查测试,以识别被认为是完全可植入的心脏逆变器纤维纤维(S-ICD)的患者。目的本研究的目的是确定ECG筛查测试失败并确定失败预测因素的潜在S-ICD受体的比例。方法已经有ICD但未接受抗纤维心动心脏起搏的方法代表了可能被认为是S-ICD的患者。一百个这样的门诊病人参加了研究。沿S-ICD系统的传感向量记录了表面节律条,并应用了筛选模板。将测试失败的患者的临床和标准心电图特征与通过的患者进行了比较。结果患者具有以下特征:男性72%,年龄57±16岁,体重指数29±6 kg/m2,左心室射血分数43%±17%,QRS持续时间109±23 ms,QTC间隔447±39 ms ,有44%的人患有冠状动脉疾病,55%患有心力衰竭。在100名患者中,8%的筛查测试失败。患者临床特征和大多数标准的心电图测量没有差异。但是,标准ECG铅I,II和AVF中具有T波反转的患者失败了45%。结论在筛查测试失败后,旨在识别容易受到T波过度敏感的患者的筛查测试失败后,有8%的潜在S-ICD患者没有资格获得S-ICD。标准心电图中I,II和AVF中T波反转的患者失败的可能性高23倍。在S-ICD传感算法中需要更多的工作以增加患者的S-ICD资格。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号