首页> 外文期刊>Blood Pressure Monitoring >Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM 7102-E), and the Omron R3-I Plus (HEM 6022-E).
【24h】

Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM 7102-E), and the Omron R3-I Plus (HEM 6022-E).

机译:根据国际协议验证了三种用于血压自我测量的自动设备:Omron M3 Intellisense(HEM-7051-E),Omron M2 Compact(HEM 7102-E)和Omron R3-I Plus(HEM 6022-E)。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Three oscillometric devices for the self blood pressure measurement were evaluated according to the International Protocol of the European Society of Hypertension in three separate studies. The Omron M3 Intellisense and the Omron M2 Compact measures blood pressure (BP) at the brachial level; the Omron R3-I Plus measures BP at the wrist level. METHODS: The International Protocol is divided into two phases and includes a total number of 33 participants on whom the validation is performed. In each study, and for each participant, four BP measurements were taken simultaneously by two observers using mercury sphygmomanometers alternately with three measurements with the tested device. The difference between the observers and the device BP values was calculated for each measurement. The 99 pairs of BP differences were classified into three categories (< or =5, < or =10, < or =15 mmHg). RESULTS: All three tested devices passed the first and second phase of the validation process. The mean differences between the device and mercury readings were 1.9+/-3.0 and -1.0+/-2.3 mmHg for systolic and diastolic BP, respectively, for the Omron M3 Intellisense device, 2.5+/-5.4 and -2.3+/-3.6 mmHg for the Omron M2 Compact device, and 1.4+/-4.5 and 0.8+/-4.6 mmHg for the Omron R3-I Plus device. CONCLUSION: Readings of the Omron M3 Intellisense, the Omron M2 Compact and the Omron R3-I Plus, differing by less than 5, 10, and 15 mmHg fulfill the International Protocol requirements and therefore can be used by patients for self blood pressure measurement.
机译:目的:根据《欧洲高血压学会国际协议》在三个单独的研究中评估了三种用于自我血压测量的示波设备。 Omron M3 Intellisense和Omron M2 Compact在肱水平测量血压(BP)。 Omron R3-I Plus在腕部测量血压。方法:《国际议定书》分为两个阶段,包括总共33位参与者,对其进行验证。在每项研究中,对于每位参与者,两名观察员交替使用水银血压计同时进行四次BP测量,并使用被测设备进行三次测量。对于每次测量,计算观察者与设备BP值之间的差异。将99对BP差异分为三类(<或= 5,<或= 10,<或= 15 mmHg)。结果:所有三个测试的设备均通过了验证过程的第一阶段和第二阶段。对于Omron M3 Intellisense装置,收缩压和舒张压的平均读数与汞读数之间的平均差异分别为1.9 +/- 3.0和-1.0 +/- 2.3 mmHg,2.5 +/- 5.4和-2.3 +/- 3.6对于Omron M2 Compact设备为mmHg,对于Omron R3-I Plus设备为1.4 +/- 4.5和0.8 +/- 4.6 mmHg。结论:Omron M3 Intellisense,Omron M2 Compact和Omron R3-I Plus的读数相差不到5、10和15 mmHg,符合国际协议的要求,因此可用于患者自测血压。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号