首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Fatigue Resistance of Nickel-titanium Instruments Exposed to High-concentration Hypochlorite
【24h】

Fatigue Resistance of Nickel-titanium Instruments Exposed to High-concentration Hypochlorite

机译:镍钛仪器暴露于高浓度次氯酸盐的疲劳性

获取原文
获取原文并翻译 | 示例
       

摘要

Abstract Introduction The purpose of this study was to introduce a new fatigue test model that simulates the clinical situation for evaluating the corrosion effect of 5.25% sodium hypochlorite (NaOCl) on nickel-titanium (NiTi) files and to evaluate the effect of 3 different temperatures (22°C, 37°C, and 60°C) on the cyclic fatigue of these files. Methods Three NiTi files (size 25/.04), K3 (SybronEndo, Orange, CA), K3XF (SybronEndo), and Vortex (Dentsply Tulsa Dental Specialties, Tulsa, OK), were subjected to cyclic fatigue tests inside a novel artificial ceramic canal with a curvature of 60° and a 5-mm radius. A 19-mm-long file segment from the tip was introduced into the canal and immersed in water or 5.25% NaOCl at 3 different temperatures, and the number of revolutions to fracture (N f ) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. Data were analyzed using univariate analysis of variance with the significance level at 0.05. Results The N f of Vortex files was the highest followed by K3XF and K3 ( P ? f of all files was highest at 22°C and lowest at 60°C ( P ? f was detected in Vortex files between 22°C and 37°C. The N f of all files in 5.25% NaOCl was shorter than that in water although there was no statistically significant difference. No pitting or crevice corrosion was observed on the fracture surface. Conclusions NaOCl, 5.25%, does not significantly affect the fatigue behavior of NiTi files. The fatigue resistance should be tested under specific temperature conditions. The austenite finish temperature of a file is important in determining the fracture risk at body temperature. Highlights ? A new fatigue test (in zirconium oxide) model that better simulates the clinical situation for the evaluation of the corrosion effect by 5.25% sodium hypochlorite (NaOCl) on nickel-titanium (NiTi) files is introduced. ? The effect of 3 different temperatures (22°C, 37°C, and 60°C) on the cyclic fatigue life of conventional superelastic and heat-treated NiTi files is evaluated. ? The fatigue life of NiTi files in 5.25% NaOCl is only slightly shorter than in water, with no statistically significant difference. ? The Vortex file with a reported high austenite finish temperature shows only a slight reduction of cyclic fatigue resistance at body temperature, whereas at 60°C the fatigue resistance is greatly reduced. ? Contrary to the Vortex file, the fatigue resistance of the K3 and K3XF files decreases clearly at body temperature. ]]>
机译:摘要简介本研究的目的是介绍一种新的疲劳试验模型,模拟临床情况,评估5.25%次氯酸钠(NaOCl)对镍钛(NiTi)锉刀的腐蚀效果,并评估3种不同温度(22℃、37℃和60℃)对这些锉刀循环疲劳的影响。方法在曲率为60°半径为5mm的新型人工陶瓷管内,对三种镍钛锉(尺寸25/.04)、K3(SybronEndo,Orange,CA)、K3XF(SybronEndo)和Vortex(Dentsply Tulsa Dental Specialties,Tulsa,OK)进行循环疲劳试验。将一段19mm长的锉刀从尖端插入根管,并在3种不同温度下浸入水或5.25%NaOCl中,记录断裂转数(NF)。用扫描电子显微镜检查所有碎片的断裂面。数据分析采用单变量方差分析,显著性水平为0.05。结果涡街锉的N f值最高,其次是K3 f和K3(P?f值在22°C时最高,在60°C时最低)(在22°C和37°C之间的涡流锉中检测到P?f。在5.25%NaOCl中,所有锉的N f均短于在水中的N f,但无统计学差异。在断裂表面上未观察到点蚀或缝隙腐蚀。结论5.25%的NaOCl不会显著影响NiTi锉的疲劳行为。应在sp下测试抗疲劳性特定的温度条件。锉刀的奥氏体终饰温度对于确定体温下的断裂风险很重要。亮点?介绍了一种新的疲劳试验(氧化锆)模型,该模型能更好地模拟临床情况,用于评估5.25%次氯酸钠(NaOCl)对镍钛(NiTi)锉刀的腐蚀效果?评估了3种不同温度(22°C、37°C和60°C)对常规超弹性和热处理镍钛锉刀循环疲劳寿命的影响?NiTi锉刀在5.25%NaOCl中的疲劳寿命仅略短于在水中的疲劳寿命,没有统计学上的显著差异?据报道,奥氏体终饰温度较高的涡流锉显示,在室温下,循环疲劳抗力仅略有降低,而在60°C下,疲劳抗力大大降低?与涡流锉相反,K3和K3XF锉的抗疲劳性在体温下明显降低。]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号