首页> 外文期刊>Journal of cardiovascular electrophysiology >Differences between cardiac implantable electronic device envelopes evaluated in an animal model
【24h】

Differences between cardiac implantable electronic device envelopes evaluated in an animal model

机译:在动物模型中评估的心脏可植入电子设备包络之间的差异

获取原文
获取原文并翻译 | 示例

摘要

Introduction Cardiac implantable electronic device (CIED) pocket related problems such as infection, hematoma, and device erosion cause significant morbidity and the clinical consequences are substantial. Bioabsorbable materials have been developed to assist in the prevention of these complications but there has not been any direct comparison of these adjunctive devices to reduce these complications. We sought to directly compare the TYRX absorbable antibacterial and CanGaroo extracellular matrix (ECM) envelopes in an animal model susceptible to these specific CIED-related complications (i.e., skin erosion and infection). Methods and Results Sixteen mice undergoing implantation with biopotential transmitters were divided into three groups (no envelope = 4, TYRX = 5, and CanGaroo = 7) and monitored for device-related complications. Following 12 weeks of implantation, gross and histological analysis of the remaining capsules was performed. Three animals in the CanGaroo group (43%) had device erosion compared to none in the TYRX group. The remaining capsules excised at 12 weeks were qualitatively thicker following CanGaroo compared to TYRX and no envelope and histological evaluation demonstrated increased connective tissue with CanGaroo. Conclusion CanGaroo ECM envelopes did not reduce the incidence of device erosion and were associated with qualitatively thicker capsules and connective tissue staining at 12 weeks compared to no envelope or TYRX. Further studies regarding the use of these envelopes to prevent device erosion and their subsequent impact on capsule formation are warranted.
机译:心脏植入式电子设备(CIED)口袋相关问题,如感染、血肿和设备侵蚀,会导致严重的发病率和临床后果。生物可吸收材料已被开发用于协助预防这些并发症,但尚未对这些辅助设备进行任何直接比较,以减少这些并发症。我们试图在易受这些特定CIED相关并发症(即皮肤侵蚀和感染)影响的动物模型中,直接比较TYRX可吸收抗菌剂和CanGaroo细胞外基质(ECM)包膜。方法和结果将16只植入生物电位传输器的小鼠分为三组(无包膜组=4,TYRX组=5,CanGaroo组=7),并监测装置相关并发症。植入12周后,对剩余胶囊进行大体和组织学分析。与TYRX组无动物相比,CanGaroo组有三只动物(43%)出现设备腐蚀。与TYRX相比,CanGaroo术后12周切除的剩余胶囊在质量上更厚,无包膜,组织学评估显示CanGaroo术后结缔组织增加。结论与无包膜或TYRX相比,CanGaroo ECM包膜并不能降低设备腐蚀的发生率,并且在12周时与质量更厚的包膜和结缔组织染色有关。关于使用这些封套防止设备腐蚀及其对胶囊形成的后续影响的进一步研究是有必要的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号