The purpose of this study is to investigate how the imposition of personalized, non-invasively measured blood flow rates as boundary conditions (BCs) influences image-based computational hemodynamic studies in the human aorta. We extracted from 4D phase-contrast MRI acquisitions of a healthy human (1) the geometry of the thoracic aorta with supra-aortic arteries and (2) flow rate waveforms at all boundaries. Flow simulations were carried out, and the implications that the imposition of different BC schemes based on the measured flow rates have on wall shear stress (WSS)-based indicators of abnormal flow were analyzed. Our results show that both the flow rate repartition among the multiple outlets of the aorta and the distribution and magnitude of the WSS-based indicators are strongly influenced by the adopted BC strategy. Keeping as reference hemodynamic model the one where the applied BC scheme allowed to obtain a satisfactory agreement between the computed and the measured flow rate waveforms, differences in WSS-based indicators up to 49% were observed when the other BC strategies were applied. In conclusion, we demonstrate that in subject-specific computational hemodynamics models of the human aorta the imposition of BC settings based on non-invasively measured flow rate waveforms influences indicators of abnormal flow to a large extent. Hence, a BCs set-up assuring realistic, subject-specific instantaneous flow rate distribution must be applied when BCs such as flow rates are prescribed.
机译:这项研究的目的是调查如何将个性化,非侵入式测量的血流速度作为边界条件(BCs)的施加如何影响人主动脉中基于图像的计算血流动力学研究。我们从健康人的4D相衬MRI采集中提取(1)带有主动脉上动脉的胸主动脉的几何形状,以及(2)所有边界处的流速波形。进行了流动模拟,并分析了基于测得的流速实施不同的BC方案对基于壁剪应力(WSS)的异常流动指标的影响。我们的结果表明,主动脉多个出口之间的流量分配以及基于WSS的指标的分布和大小都受到采用的BC策略的强烈影响。将应用的BC方案允许在计算的流量波形和测量的流量波形之间获得令人满意的一致性作为参考血液动力学模型,当采用其他BC策略时,观察到基于WSS的指标差异高达49%。总而言之,我们证明了在人类主动脉的特定受试者计算血液动力学模型中,基于非侵入式测量的流量波形的BC设置的施加在很大程度上影响了异常流量的指标。因此,当规定了诸如流速之类的BC时,必须应用BCs设置以确保现实的,特定于受试者的瞬时流速分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号