Variation of mass (volume) taken with the calibrated syringe and of the results provided by the Bio-Rad Platelia~(TM) BSE test upon storage of brainstem samples at -20 deg C

机译:在-20℃下储存脑干样品时,使用校准过的注射器采集的质量(体积)的变化以及Bio-Rad Platelia〜(TM)BSE测试提供的结果的变化

获取原文
获取原文并翻译 | 示例
           

摘要

The real mass obtained by sampling with the calibrated syringe provided by the supplier, and the degradation through cold storage was evaluated in view of the measured optical density of suspected bovine BSE brainstem material in the quick Platelia~(TM) test from Bio-Rad. For this, 50 negative BSE cases and 2 positive BSE cases were tested. The brainstems were stored at -20 deg C and the weight of each sample was taken with a calibrated syringe at an interval of 1 week. Moreover, the final opticaldensity obtained with the quick Platelia~(TM) ELISA lest of each case was evaluated. This was done three times for each case (brainstem), including the primary sampling of the fresh brainstem tissue taken immediately after slaughter. The results indicatethat storage at -20 deg C gives a significant decrease in weight of the mass taken with the calibrated syringe (P = 0.0121) and in optical density (P < 0.001) between the fresh and 1 week old sample for the same volume. This decrease did not seem to continue significantly after this first week of storage. Furthermore, no significant correlation could be noted between the decrease in the weight of the mass (volume) taken between the fresh sample and the sample taken after 1 - week storage and the decrease in optical density of the respective negative samples. Our results therefore suggest that there is a significant decrease in optical density after 1 - week cold storage, but that this could not be associated with the concurrent decrease in weight of the mass (volume) taken by the calibrated syringe. However, this decrease in optical density did not influence the final diagnosis of BSE, using the ELISA (Platelia~(TM)) test. Additionally, this study also implicated the reliability of the calibrated syringe provided in the test kit.
机译:考虑到在Bio-Rad的快速PlateliaTM测试中,通过测量怀疑的牛BSE脑干材料的光密度,评估了通过使用供应商提供的校准注射器进行采样获得的实际质量,以及通过冷藏保存的降解。为此,测试了50例BSE阴性病例和2例BSE阳性病例。将脑干保存在-20摄氏度下,并在1周的间隔内用校准的注射器采集每个样品的重量。此外,评估了每种情况下通过快速Platelia-TM ELISA获得的最终光密度。每种情况(脑干)都要进行三次,包括在屠宰后立即采集新鲜的脑干组织。结果表明,在相同温度下,在-20℃下储存,可以显着减少使用校准注射器采集的质量的重量(P = 0.0121)和新鲜和1周龄样品之间的光密度(P <0.001)。在存储的第一周后,这种下降似乎并未继续明显。此外,在新鲜样品和储存1周后采集的样品之间所采集的质量(体积)的重量的减少与各个阴性样品的光学密度的降低之间没有明显的相关性。因此,我们的结果表明,冷藏1周后,光密度显着降低,但这与校准后的注射器的质量(体积)重量的同时降低没有关系。但是,使用ELISA(PlateliaTM)测试,光密度的这种降低不会影响BSE的最终诊断。此外,这项研究还暗示了测试套件中提供的校准注射器的可靠性。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号