首页> 外文期刊>Analytical methods >Dispersive liquid - liquid microextraction followed by high performance liquid chromatography for determination of phthalic esters in environmental water samples
【24h】

Dispersive liquid - liquid microextraction followed by high performance liquid chromatography for determination of phthalic esters in environmental water samples

机译:分散液-液微萃取-高效液相色谱法测定环境水样中的邻苯二甲酸酯

获取原文
获取原文并翻译 | 示例
           

摘要

A new method was developed for the simultaneous determination of six phthalic acid esters (PAEs) in different environmental water samples using salt-assisted dispersive liquid-liquid microextraction with carbon tetrachloride as an extraction solvent and acetonitrile as a dispersive solvent coupled with high performance liquid chromatography with UV detection. The influence of the added NaCl on the enrichment factor (EF) in DLLME was investigated. The salting-out effect causes the hydrophobicity of organic analytes to be increased and high EFs to be more pronounced than those in salt-free water. Greater EF, wider linearity, better recovery, smaller relative standard deviation (RSD) and lower limit of detection were obtained at higher concentration of NaCl. Under optimized extraction conditions, good linearity was observed for all analytes in a range of 1.00-100 μg L~(-1) with the correlation coefficient (r~2) &0.9992. The limits of detection based on the signal to noise ratio of 3 were 0.01-0.03 μg L~(-1). The recoveries of PAEs were 97.5-105.5% for spiked water with 20 μg L~(-1) of PAEs. The repeatability of the proposed method expressed as RSDs ranged from 3.13 to 5.32% (n = 3). EFs are in the range of 78 to 262 fold. The method was applied to the determination of PAEs in water samples from local river, rain and urban wastewater treatment plants with the standard addition, the recoveries of PAEs were 86.2-105.0%, 93.8-107.0% and 92.4-106.3%, and the RSDs were below 6.79%. The current procedure afforded a convenient, inexpensive and reliable sample preparation with high extraction efficiency for trace PAEs in environmental water samples.
机译:开发了一种新方法,同时使用四氯化碳作为萃取溶剂,乙腈作为分散溶剂的盐辅助分散液-液微萃取与高效液相色谱法同时测定不同环境水样品中的六种邻苯二甲酸酯(PAE)。带有紫外线检测。研究了添加的NaCl对DLLME中富集因子(EF)的影响。盐析效应导致有机分析物的疏水性增加,而高EFs比无盐水中的EFs更明显。在较高的NaCl浓度下,可以获得更高的EF,更宽的线性,更好的回收率,更小的相对标准偏差(RSD)和更低的检测限。在最佳提取条件下,所有分析物在1.00-100μgL〜(-1)范围内均具有良好的线性,相关系数(r〜2)&0.9992。基于3的信噪比的检测限为0.01-0.03μgL〜(-1)。加有20μgL〜(-1)的加标水,加标水的PAE回收率为97.5-105.5%。表示为RSD的拟议方法的可重复性范围为3.13%至5.32%(n = 3)。 EF在78到262倍之间。该方法适用于标准添加量的地方河流,雨水和城市废水处理厂水样中PAE的测定,PAE的回收率分别为86.2-105.0%,93.8-107.0%和92.4-106.3%,以及RSD低于6.79%。当前的程序为环境水样品中的痕量PAE提供了一种方便,廉价且可靠的样品制备方法,并具有较高的提取效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号