...
首页> 外文期刊>Rapid Communications in Mass Spectrometry: RCM >External trap-and-release membrane inlet for photoionization mass spectrometry: Towards fast direct analysis of aromatic pollutants in aquatic systems
【24h】

External trap-and-release membrane inlet for photoionization mass spectrometry: Towards fast direct analysis of aromatic pollutants in aquatic systems

机译:外部捕获质谱法的外部捕获和释放膜入口:水产系统中芳香族污染物的快速直接分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Rationale Fast and sensitive detection of aromatic hydrocarbons (AHs) in water is of high importance because of their significant impact on human health and the environment. For this, resonance-enhanced multiphoton ionization (REMPI) coupled to trap-and-release membrane-introduction mass spectrometry (T&R-MIMS) offers the possibility of sensitive on-line water analysis with a time resolution of minutes. Methods REMPI is a versatile tool for sensitive gas-phase analysis, in which AHs are selectively ionized in complex gas mixtures by the subsequent absorption of at least two photons. In T&R-MIMS, selective extraction and enrichment of analytes from water can be achieved using semipermeable membranes. By the subsequent stimulated desorption of enriched compounds, mass spectrometric detection is enabled. Results We present an external T&R inlet for hollow-fiber membranes coupled to REMPI time-of-flight mass spectrometry, which enables direct and sensitive detection of semi-volatile AHs in water. In laboratory experiments, spiked water samples were analyzed. For the investigated compounds, limits of detection (LODs) in the range 1-47 ng/L were determined. The LODs are approximately one order of magnitude lower than in a previously reported continuous membrane-introduction approach using a planar membrane. Further improvement of LOD may be realized by extending the trapping time and by increasing the release temperature. Furthermore, the system was applied to investigate different fuels suspended in water and real water samples. The obtained data are in good agreement with findings of a former study. Conclusions In the framework of the present study, we demonstrate the high potential of the combination of REMPI and T&R-MIMS in the form of a newly developed external hollow-fiber membrane inlet. With the developed system, semi-volatile AHs can be directly detected down to ng/L levels on a minute time scale. The approach thus may pave the way to future ship application in marine sciences, natural resources exploration or pollutant and hazard detection.
机译:None

著录项

  • 来源
  • 作者单位

    Univ Rostock Inst Chem Chair Analyt Chem Joint Mass Spectrometry Ctr Dr Lorenz Weg 2 D-18059 Rostock Germany;

    Univ Rostock Inst Chem Chair Analyt Chem Joint Mass Spectrometry Ctr Dr Lorenz Weg 2 D-18059 Rostock Germany;

    Photon GmbH Hagenower Str 73 D-19061 Schwerin Germany;

    Leibniz Inst Balt Sea Res Warnemunde Seestr 15 D-18119 Rostock Germany;

    Univ Rostock Inst Chem Chair Analyt Chem Joint Mass Spectrometry Ctr Dr Lorenz Weg 2 D-18059 Rostock Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号