首页> 外文期刊>Investigative radiology >Evaluation of the Reproducibility of Bolus Transit Quantification With Contrast-Enhanced Ultrasound Across Multiple Scanners and Analysis Software Packages-A Quantitative Imaging Biomarker Alliance Study
【24h】

Evaluation of the Reproducibility of Bolus Transit Quantification With Contrast-Enhanced Ultrasound Across Multiple Scanners and Analysis Software Packages-A Quantitative Imaging Biomarker Alliance Study

机译:对多个扫描仪对比度增强超声的评估Zolus过境量化的再现性和分析软件包 - 定量成像生物标志物联盟研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives Contrast enhanced ultrasound (CEUS) is now broadly used clinically for liver lesion detection and characterization. Obstacles to the efforts to quantify perfusion with CEUS have been the lack of a standardized approach and undocumented reproducibility. The use of multiple scanners and different analysis software packages compounds the degree of variability. Our objectives were to standardize a CEUS-based approach for quantification of perfusion-related parameters of liver lesions and to evaluate the variability of bolus transit parameters (rise time [RT], mean transit time [MTT], peak intensity, and area under the curve) obtained from various clinical ultrasound scanners and analysis software. Materials and Methods Bolus transit as a way of evaluating perfusion has been investigated both in vivo and in vitro in the past but without establishing its reproducibility. We developed a tissue flow phantom that produces time-intensity curves very similar to those extracted from clinical cine loops of liver lesions. We evaluated the variability of the bolus transit parameters with 4 commercial scanners (Philips iU22, Philips EPIQ, GE LOGIQ E9, and Siemens Acuson Sequoia) and 3 different analysis software packages in multiple trials (15 per scanner). Results The variability (coefficient of variation) from repeated trials and while using a single scanner and software was less than 8% for RT, less than 12% for MTT, less than 49% for peak intensity, and less than 50% for area under the curve. Currently, it is not possible to directly compare amplitude values from different scanners and analysis software packages owing to the arbitrary linearization algorithm used among manufacturers; however, it is possible for time parameters (RT and MTT). The variability when using a different scanner with the same analysis software package was less than 9% for RT and less than 21% for MTT. The variability when using a different analysis software with the same scanner was less than 9% for RT and less than 15% for MTT. In all the evaluations we have performed, RT is the least variable parameter, while MTT is only slightly more variable. Conclusions The present study will lay the groundwork for multicenter patient evaluations with CEUS quantification of perfusion-related parameters with the bolus transit technique. When using the protocol and method developed here, it is possible to perform perfusion quantification on different scanners and analysis software and be able to compare the results. The current work is the first study that presents a comparison of bolus transit parameters derived from multiple systems and software packages.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号