Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation

机译:五到十三年的水泥双移动性插座的结果治疗复发性错位

获取原文
获取原文并翻译 | 示例
       

摘要

Abstract Purpose Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. Methods The series included 51 patients with a mean age of 71.3?±?11.5 (range, 41–98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. Results At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8?±?2.3?years, three were lost to follow-up at a mean of 1.4?years, seven had been revised at a mean of 4.7?±?3.1?years (range, 1.5–9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2?±?2.4?years (range, 5–13?years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9?±?2.9?years (range, 2.7–9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten?years, using re-dislocation as the end-point, was 86.1?±?8.4% (95% confidence interval, 69.7–100%). The survival rate of the cup at ten?years, using revision for any reason as the end-point, was 75.2?±?9.3% (95% confidence interval, 56.9–93.5%). Conclusion A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten?years was related to this specific patients population that had various co-morbidities.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号