首页> 外文期刊>Analytical methods >Ionic liquid based in situ solvent formation microextraction followed by on-line phase separation coupled with cold vapor-atomic absorption spectrometry for mercury determination in seafood samples
【24h】

Ionic liquid based in situ solvent formation microextraction followed by on-line phase separation coupled with cold vapor-atomic absorption spectrometry for mercury determination in seafood samples

机译:基于原位溶剂形成微萃取的离子液体,随后与冷蒸气原子吸收光谱相连,汞测定在海鲜样品中

获取原文
获取原文并翻译 | 示例
           

摘要

Ionic liquid based in situ solvent formation microextraction (IL-ISFME) followed by on-line phase separation coupled to cold vapor-atomic absorption spectrometry (CV-AAS) was introduced based on using a homemade in-line filter for phase separation. In this method, low cost and easy to access PTFE powder, as an industrial raw material, was used to fill a medical syringe and applied for the separation of hydrophobic ionic liquid containing analytes. The developed methodology is simple and eliminates the application of centrifugation in the phase separation step to overcome some limitations of emulsification techniques. In IL-ISFME an ion-pairing agent was added to a sample solution containing hydrophilic IL. In the following, the fine droplets of hydrophobic IL made by the promotion of a metathesis reaction were recovered via an in-line filter. To show the applicability of the proposed method, it was applied for the extraction and determination of mercury in seafood samples. The effects of some important parameters were investigated and optimized using a central composite design (CCD). Under the optimized conditions, the linearity of the method was obtained over a range of 2-200 mu g L-1 with a determination coefficient (R-2) higher than 0.996. The enrichment factor (EF) and absolute recovery (AR%) of the method achieved were 5.7 and 57.3%, respectively. The limits of detection (LOD) and quantification (LOQ) were found to be 0.6 and 2.0 mu g L-1 respectively. The intraand inter-day precisions expressed as relative standard deviations (RSD%, n = 3) were 4.8% and 7.6%, respectively. The relative recoveries (RR%) obtained were in the range of 80 to 90.5%, which correspond to the relative errors of -20% to -=9.5%, respectively, confirming the achievement of satisfactory accuracies by the proposed procedure.
机译:None

著录项

  • 来源
    《Analytical methods》 |2017年第35期|共9页
  • 作者单位

    Kharazmi Univ Fac Chem 43 Mofateh Ave Tehran 1571914911 Iran;

    KN Toosi Univ Technol Dept Analyt Chem Fac Chem Tehran 163151355 Iran;

    Iranian Natl Inst Oceanog &

    Atmospher Sci 3 Etemadzadeh St Fatemi Ave Tehran 1411813389 Iran;

    Kharazmi Univ Fac Chem 43 Mofateh Ave Tehran 1571914911 Iran;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号