A new method has been developed for field screening of copper (II) in water samples, which is based on an enzyme inhibition reaction between copper (II) and nitrate reductase. The concentration of copper ( II) was acquired by indirect determination the reaction product (nitrite) with a mini optical reflection sensor. Under the optimum conditions, the calibration graph was linear in the range of 5.0 - 50 ng mL(-1). The limit of detection was 0.5 ng mL(-1). This method has been used for the field screening of copper (II) with satisfactory results.
机译:基于铜(II)和硝酸盐还原酶之间的酶抑制反应,已经开发了一种新方法用于现场筛选水中的铜(II)。通过使用微型光学反射传感器间接测定反应产物(亚硝酸盐)来获得铜(II)的浓度。在最佳条件下,校准曲线在5.0-50 ng mL(-1)范围内呈线性关系。检测限为0.5 ng mL(-1)。该方法已用于铜(II)的现场筛选,结果令人满意。