Gold nanoparticles modified titania nanotube arrays for amperometric determination of ascorbic acid

机译:金纳米粒子修饰的二氧化钛纳米管阵列用于抗坏血酸的安培测定

获取原文
获取原文并翻译 | 示例

摘要

Development and use of highly ordered, vertically aligned TiO_2 nanotube arrays modified with gold nanoparticles for the selective detection of ascorbic acid (AA) in the presence of uric acid and glucose are reported here. Gold nanoparticles were electrodeposited on the Nanotube arrays by CV. The sensor was characterized using SEM, EDS, CV, and EIS. It showed very good performance with a sensitivity of 46.8 μA mM~(-1) cm~(-2), response time below 2 seconds and linearity in the range of 1 μM to 5mM with a detection limit of 0.1 μM and was tested for the AA concentration in pharmaceutical preparations.
机译:本文报道了用金纳米颗粒修饰的高度有序的,垂直排列的TiO_2纳米管阵列的开发和使用,用于在尿酸和葡萄糖存在下选择性检测抗坏血酸(AA)。通过CV将金纳米颗粒电沉积在纳米管阵列上。使用SEM,EDS,CV和EIS对传感器进行了表征。它显示出非常好的性能,灵敏度为46.8μAmM〜(-1)cm〜(-2),响应时间低于2秒,线性范围为1μM至5mM,检测极限为0.1μM,并进行了测试药物制剂中的AA浓度。