首页> 外文期刊>Biocybernetics and biomedical engineering >An objective method to identify optimum clip-limit and histogram specification of contrast limited adaptive histogram equalization for MR images
【24h】

An objective method to identify optimum clip-limit and histogram specification of contrast limited adaptive histogram equalization for MR images

机译:识别MR图像对比度有限自适应直方图均衡的最佳剪辑限制和直方图规范的目标方法

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract In contrast limited adaptive histogram equalization (CLAHE), the selection of tile size, clip-limit and the distribution which specify desired shape of the histogram of image tiles is paramount, as it critically influences the quality of the enhanced image. The optimal value of these parameters devolves on the generic of the image to be enhanced and usually they are selected empirically. In this paper, the degradation of intensity, textural and geometric features of the medical image with respect to the variation in clip-limit and specified histogram shape is analyzed. The statistical indices used to quantify the feature degradation are Absolute Mean Brightness Error (AMBE), Absolute Deviation in Entropy (ADE), Peak Signal to Noise Ratio (PSNR), Variance Ratio (VR), Structural Similarity Index Matrix (SSIM) and Saturation Evaluation Index (SEI). The images used for the analysis are axial plane MR images of magnetic resonance spectroscopy (MRS), under gradient recalled echo (GRE), diffusion weighted imaging (DWI) 1000b Array Spatial Sensitivity Encoding Technique (ASSET), T2 Fluid Attenuation Inversion Recovery (FLAIR) and T1 Fast Spin-Echo Contrast Enhanced (FS-ECE) series of pre-operative Glioblastoma-edema complex. The experimental analysis was performed using Matlab ? . Results show that for MR images the exponential histogram specification with a clip-limit of 0.01 is found to be optimum. At optimum clip-limit, the mean of SSIM exhibited by the Rayleigh, uniform and exponential histogram specification were found to be 0.7477, 0.7946 and 0.8457, for ten sets of MR images and mean of variance ratio are 1.242, 2.0316 and 1.7711, respectively.
机译:摘要在对比度有限的自适应直方图均衡(CLAHE),瓷砖尺寸的选择,剪辑限制和指定图像瓦片直方图的所需形状的分布是至关重要的,因为它批判性地影响增强图像的质量。这些参数的最佳值在要增强的图像的通用上ovolves,通常它们是凭经验选择的。在本文中,分析了医学图像相对于夹子限制和指定直方图形状的变化的强度,纹理和几何特征的劣化。用于量化特征劣化的统计指标是绝对的平均亮度误差(AMBE),熵(ADE)的绝对偏差,峰值信号到噪声比(PSNR),方差比(VR),结构相似度指数矩阵(SSIM)和饱和度评估指数(SEI)。用于分析的图像是磁共振光谱(MRS)的轴向平面MR图像,在梯度召回的回声(GRE)下,扩散加权成像(DWI)1000B阵列空间敏感性编码技术(资产),T2流体衰减反转恢复(Flair )和T1快速旋转回波对比增强(FS-ECE)术前胶质母细胞瘤 - 水肿复合物。使用matlab进行实验分析? 。结果表明,对于MR图像,发现具有0.01的剪辑限制的指数直方图规范是最佳的。在最佳夹子限制下,瑞利,均匀和指数直方图规范表现出的SSIM的平均值为0.7477,0.7946和0.8457,对于十组MR图像和方差均值分别为1.242,2.0316和1.7711。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号