...
首页> 外文期刊>Biomedical Chromatography: An International Journal Devoted to Research in Chromatographic Methodologies and Their Applications in the Biosciences >An LC-MS/MS method for quantitation of cyanidin-3-O-glucoside in rat plasma: Application to a comparative pharmacokinetic study in normal and streptozotocin-induced diabetic rats
【24h】

An LC-MS/MS method for quantitation of cyanidin-3-O-glucoside in rat plasma: Application to a comparative pharmacokinetic study in normal and streptozotocin-induced diabetic rats

机译:大鼠血浆中Cyanidin-3-O-葡糖苷的定量LC-MS / MS方法:在正常和链脲佐菌素诱导的糖尿病大鼠中应用于对比药代动力学研究

获取原文
获取原文并翻译 | 示例
           

摘要

A sensitive and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to determine cyanidin-3-O-glucoside (Cy-3G) in normal and streptozotocin-induced diabetic rat plasma. Chromatographic separation was carried out on a Zorbax SB-C-18 (50 x 4.6 mm, 5 mu m) column and mass spectrometric analysis was performed using a Thermo Finnigan TSQ Quantum Ultra triple-quadrupole mass spectrometer coupled with an ESI source in the negative ion mode. Selected reaction monitoring mode was applied for quantification using target fragment ions m/z 447.3 - 285.2 for Cy-3G and m/z 463.0 - 300.1 for quercetin-3-O-glucoside (internal standard). The calibration curve was linear over the range 3.00-2700 ng/mL (r(2) = 0.99) with the lower limit of quantitation at 3.00 ng/mL. Intra- and inter-day precision was 14.5% and mean accuracy was from -11.5 to 13.6%. Stability testing showed that Cy-3G remained stable during the whole analytical procedure. After validation, the assay was successfully used to support a preclinical pharmacokinetic comparison of Cy-3G between normal and diabetic rats. Results indicated that diabetes mellitus significantly altered the in vivo pharmacokinetic characteristics of Cy-3G after oral administration in rats.
机译:开发了一种敏感且可靠的液相色谱串联质谱(LC-MS / MS)方法以确定正常和链脲佐菌素诱导的糖尿病大鼠等离子体中的花生素-3-O-葡糖苷(Cy-3G)。在Zorbax Sb-C-18(50×4.6mm,5μm)柱上进行色谱分离,使用热芬兰TSQ量子超三倍轴质谱仪进行质谱分析,耦合在负面的eSI源离子模式。使用靶碎片离子M / Z 447.3 - &gt施用所选反应监测模式。 285.2用于CY-3G和M / Z 463.0 - > 300.1用于槲皮素-3-O-葡糖苷(内标)。校准曲线在3.00-2700ng / ml(R(2)& = 0.99)的范围内是线性的,其定量下限为3.00 ng / ml。在日内和白间精度是& 14.5%和平均准确度为-11.5至13.6%。稳定性测试表明,整个分析过程中Cy-3G保持稳定。验证后,分析成功用于支持正常和糖尿病大鼠之间Cy-3G的临床前药代动力学比较。结果表明,糖尿病在大鼠口服施用后Cy-3g的体内药代动力学特征显着改变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号