首页> 外文期刊>Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine >Peak-to-valley ratios for three different HPGe detectors for the assessment of 137Cs deposition on the ground and the impact of the detector field-of-view
【24h】

Peak-to-valley ratios for three different HPGe detectors for the assessment of 137Cs deposition on the ground and the impact of the detector field-of-view

机译:用于三种不同HPGE探测器的峰谷比率,用于评估137CS沉积在地面上和探测器视野的影响

获取原文
获取原文并翻译 | 示例

摘要

The peak-to-valley (PTV) method was investigated experimentally comparing PTV ratios for three HPGe detectors, with complementary Monte Carlo simulations of scatter in air for larger source-detector distances. The measured PTV ratios for 137Cs in air were similar for three different detectors for incident angles between 0 and 90 degrees. The study indicated that the PTV method can differentiate between surface and shallow depth sources if the detector field of view is limited to a radius of less than 3.5 m.
机译:研究了峰 - 谷(PTV)方法对三个HPGE探测器的PTV比进行了实验比较,具有互补的蒙特卡罗模拟空气中的散射,用于较大的源极探测器距离。 对于在0到90度之间的入射角的三种不同的探测器中,空气中的137℃的测量PTV比率类似。 该研究表明,如果检测器视场限制为小于3.5米的半径,则PTV方法可以区分表面和浅深度。