The wettability characteristic of wet channels plays an important role in cooling performance of an indirect evaporative cooler (IEC). To improve its wettability, porous ceramic is used as a novel material for IEC. The porous structure provides hydrophilic feature and water storage capacity. Therefore, the wet-bulb efficiency of the cooler can be improved because of higher wettability and larger specific surface area. This paper presents a theoretical and experimental study on a tubular porous ceramic IEC. The mathematical model of heat and mass transfer was established and numerically solved to evaluate its cooling performance. The influence of various structural parameters and operational parameters of porous ceramic IEC are analyzed, including the tube length, tube spacing, wall thickness, wet-bulb temperature depression and working/output air volume ratio. The experimental study is also carried out, on one hand, to validate the numerical model; and on the other hand, to optimize the working air/product air flow ratio. The results indicate the optimal tube spacing is 40 mm. The tube length plays a significant effect on the cooling performance of IEC when it is less than 1.5 m. Experimental study shows the optimal performance of porous ceramic IEC prototype is achieved under the product air velocity of 3.4 m/s, working air velocity of 4.0 m/s and the working air/product air volume ratio of 0.9.
机译:湿信道的润湿性特性在间接蒸发冷却器(IEC)的冷却性能方面起着重要作用。为了提高其润湿性,多孔陶瓷用作IEC的新型材料。多孔结构提供亲水特征和储水能力。因此,由于更高的润湿性和更大的比表面积,可以提高冷却器的湿灯泡效率。本文介绍了对管状多孔陶瓷IEC的理论和实验研究。建立了热量和传质的数学模型,数值求解,以评估其冷却性能。分析了多孔陶瓷IEC的各种结构参数和操作参数的影响,包括管长度,管间距,壁厚,湿灯泡温度凹陷和工作/输出空气量比。一方面还进行了实验研究以验证数值模型;另一方面,优化工作空气/产品空气流量比。结果表明最佳管间距为40毫米。管长对IEC小于1.5米的冷却性能起显着影响。实验研究显示了多孔陶瓷IEC原型的最佳性能在产品空气速度为3.4 m / s,工作空气速度为4.0 m / s,工作空气/产品空气量比为0.9。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号