Experiments on the performance of bubble pumps with R134a/R23-DMF solutions for diffusion absorption refrigerator

机译:用于扩散吸收冰箱的R134A / R23-DMF解决方案的泡沫泵性能的实验

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Experiments on the performance of a bubble pump for diffusion absorption refrigerator with different lifting tubes (diameter of 8 mm and 10 mm), different filling compositions of R134a/R23 (35%/0%, 33.5%/4%, 32.2%/8%, and 30.8%/12%) and different heads (0.51 m, 0.54 m, 0.57 m, 0.6 m and 0.63 m) were conducted. The range of heat input was 233-1080 W. The experimental results revealed that: (1) larger heat input and lower head resulted in not only larger gas mass flow rate, but also higher generating temperature; (2) larger gas mass flow rate and lower head led to smaller pumping ratio; (3) the system pressure increased with mass fraction of R23; (4) at the same R134a/R23 mass fraction and head, the operation ranges of the 10 mm lifting tube were wider than those for the 8 mm lifting tube considering of pumping ratio, poor solution mass flow rate and gas mass flow rate. These results will be helpful to the design of bubble pumps for diffusion absorption refrigerators working with binary refrigerants.
机译:对不同提升管(直径为8mm和10mm)的扩散吸收冰箱的泡沫泵的性能试验,R134A / R23的不同填充组合物(35%/ 0%,33.5%/ 4%,32.2%/ 8将%和30.8%/ 12%)和不同的头部(0.51μm,0.54m,0.57m,0.6 m和0.63μm)进行。热量输入的范围为233-1080W。实验结果表明:(1)较大的热输入和下部头部导致较大的气体质量流量,而且产生更高的产生温度; (2)较大的气体质量流量和下头导致较小的泵送比; (3)系统压力随着R23的质量分数而增加; (4)在相同的R134A / R23质量分数和头部,10mm提升管的操作范围比考虑泵浦比的8mm提升管的操作范围,溶液质量流量不良和气体质量流速。这些结果将有助于设计与二元制冷剂一起使用的扩散吸收冰箱的气泡泵。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号