首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Experimental investigation on flow patterns and absorption height in a vertical bubble absorber with R124-NMP pair and comparison for R124-DMAC pair
【24h】

Experimental investigation on flow patterns and absorption height in a vertical bubble absorber with R124-NMP pair and comparison for R124-DMAC pair

机译:R124-NMP对垂直气泡吸收器流动模式和吸收高度的实验研究及R124-DMAC对的比较

获取原文
获取原文并翻译 | 示例

摘要

A visual experimental research was conducted to investigate the flow patterns and absorption height (AH) in a vertical bubble absorption tube employing R124-NMP as working fluid. The effects of various operation parameters, solution inlet mass concentration, temperature and volumetric flow rate, vapor volumetric flow rate, absorption pressure and orifice diameter, on the flow patterns and AH were examined. The key operation parameters were all converted into dimensionless numbers and the influences of dimensionless operation parameters on dimensionless absorption height (DAH) were studied. The results showed that the AH increases with increasing solution inlet mass concentration and temperature, vapor volumetric flow rate and orifice diameter and decreases with increasing solution volumetric flow rate and absorption pressure. DAB exhibits nearly linear change along with dimensionless operation parameters. Comparisons between the flow patterns and AH of R124-NMP and R124-DMAC were performed. The compared results illustrated that employing R124-NMP as working fluid can shrink the vertical bubble absorber size. Finally, the experimental correlations of AH and DAH were developed with +/- 20% and +/- 15% error bands, respectively. The correlation of DAH maybe used to predict absorption height in the design of bubble absorber employing refrigerant-organic absorbent as working fluid.
机译:进行了视觉实验研究,以研究采用R124-NMP作为工作流体的垂直气泡吸收管中的流动模式和吸收高度(AH)。研究了各种操作参数,溶液入口质量浓度,温度和体积流量,蒸汽体积流量,吸收压力和孔口直径的效果。关键操作参数全部转换成无量纲数,研究了无量纲操作参数对无量纲吸收高度(DAH)的影响。结果表明,随着溶液入口质量浓度和温度,蒸汽体积流速和孔口直径的增加,AH增加,随着溶液体积流速和吸收压力的增加而降低。 DAB展示几乎线性变化以及无量纲操作参数。进行R124-NMP和R124-DMAC的流动模式和AH之间的比较。所示的比较结果示出了使用R124-NMP作为工作流体可以缩小垂直气泡吸收体尺寸。最后,AH和DAH的实验相关性分别与+/- 20%和+/- 15%的误差带开发。 DAH的相关性可以用于预测使用制冷剂 - 有机吸收剂作为工作流体的气泡吸收器设计中的吸收高度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号