首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Simulation-based comparative seasonal performance evaluation of single-stage heat pump and modulated two-stage injection heat pump using rotary compressors with various cylinder volume ratios
【24h】

Simulation-based comparative seasonal performance evaluation of single-stage heat pump and modulated two-stage injection heat pump using rotary compressors with various cylinder volume ratios

机译:基于模拟的比较季节性性能评估单级热泵,使用具有各种气缸体积比的旋转压缩机调制两级注射热泵

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, the comparative seasonal performance evaluations of single-stage heat pump, two-stage injection heat pump, and modulated two-stage injection heat pump using rotary compressors are conducted using a heat pump simulation model. The heat pump simulation and optimization models are developed and validated. The operating parameters are optimized by genetic algorithm to achieve the maximum energy efficiency ratio (EER) and coefficient of performance (COP) at a given outdoor temperature. Moreover, the optimal lower compressor volume and cylinder volume ratio are determined to maximize the seasonal EER (SEER) and seasonal COP (SCOP) at the given weather conditions. The EER and COP of the two-stage injection heat pump are improved substantially at high cooling and heating load conditions, respectively. However, since the two-stage injection heat pump is not effective to improve the SEER owing to the lower performance at the low cooling load conditions, the modulated two-stage injection heat pump is introduced. Consequently, the SEER and SCOP of the modulated two-stage injection heat pump are 6.0% and 1.4%, respectively, higher than those of the single-stage heat pump at the cooling and average heating conditions.
机译:在本研究中,使用热泵仿真模型进行单级热泵,两级喷射热泵和调制两级注射热泵的比较季节性性能评估。开发和验证了热泵仿真和优化模型。通过遗传算法优化操作参数,以实现给定室外温度的最大能效比(EER)和性能系数(COP)。此外,确定最佳降低的压缩机容积和汽缸体积比以在给定的天气条件下最大化季节性eer(SEER)和季节性警察(SCOP)。两级喷射热泵的eer和cop分别在高冷却和加热负荷条件下基本上改善。然而,由于两级注射热泵由于低冷却负载条件下的性能下降而不错改善SEER,因此引入了调制的两级喷射热泵。因此,调制的两级注射热泵的SER和SCOP分别为6.0%和1.4%,高于冷却和平均加热条件下的单级热泵的SCOP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号