...
首页> 外文期刊>Analytical and bioanalytical chemistry >Fully automated focused infrared microashing combined with use of ICP-based instruments for rapid analysis of multiple elements in biological samples
【24h】

Fully automated focused infrared microashing combined with use of ICP-based instruments for rapid analysis of multiple elements in biological samples

机译:完全自动聚焦红外线微型混合使用基于ICP的仪器,用于快速分析生物样品中的多个元素

获取原文
获取原文并翻译 | 示例

摘要

AbstractA fully automated focused infrared microashing sample preparation system was proposed for preparation of biological samples with high organic matter content for the determination of multiple elements combined with inductively coupled plasma optical emission spectroscopy and inductively coupled plasma mass spectrometry. The whole ashing procedure, including sample transfer, carbonization and oxidation of the sample, dissolution of ash, constant volume control, and homogenization of the solution, was automatically controlled. Gold-plated infrared tubes were used to produce and focus infrared radiation to heat the sample. Ozone was used to accelerate the carbonization of samples at a lower temperature to avoid the production of large amounts of empyreumatic oil. In addition, the self-designed double-layer tube serves as a site for ashing and carbonization of the sample and as a container for dissolving ash, as well as for holding the solution. This is the only container in the entire system to reduce the risk of pollution. Eight biological certified reference materials were used as examples to evaluate the performance of the proposed device. A sample ashing pretreatment cycle, from solid sample to liquid solution, took only 40 min and simultaneously treated 12 samples. Except for individual results, the relative errors between the certified values and recorded values for 38 micro and trace elements, including Ca, Mg, Na, P, Li, Be, Sc, Ti, V, Mn, Co, Ni, Cu, Zn, Rb, Sr, Y, Mo, Ag, Cs, Ba, Tl, Th, U, and rare earth elements, were typically less than 30%. The relative standard deviations for five determinations were typically less than 15%.
Graphical abstractAutomated dry ashing sample preparation system. ICP inductiv
机译:<![cdata [ <标题>抽象 ara id =“par1”>提出了一个全自动的聚焦红外微内测量样品制备系统用于制备具有高有机物质含量的生物样品,用于测定多个元件与电感耦合等离子体光发射光谱和电感耦合等离子体质谱法相结合。自动控制整个灰化程序,包括样品转移,碳化和氧化,灰分溶解,溶液溶解和溶液均质化。使用镀金红外线管来生产和聚焦红外辐射以加热样品。臭氧用于在较低温度下加速样品的碳化,以避免生产大量的鸡尾酒。另外,自行设计的双层管用作样品的灰化和碳化的部位,以及用于溶解灰分的容器,以及保持溶液。这是整个系统中唯一的容器,以降低污染风险。使用八种生物认证参考资料作为评估所提出的装置的性能。从固体样品到液体溶液的样品灰化预处理循环仅服用40分钟并同时处理12个样品。除各个结果外,38个微型和跟踪元素的认证值与记录值之间的相对误差,包括Ca,Mg,Na,P,Li,Be,Sc,Ti,V,Mn,Co,Ni,Cu,Zn ,Rb,Sr,Y,Mo,Ag,Cs,Ba,T1,Th,U和稀土元素通常小于30%。五个测定的相对标准偏差通常小于15%。 ara id =“par2”> <图类别=“标准”float =“no”id =“figa”> <标题语言=“en “> 图形抽象 自动干灰化样品制备系统。 ICP Infuctiv.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号