首页> 外文期刊>Analytical chemistry >Guidelines for Selection of Internal Standard-Based Normalization Strategies in Untargeted Lipidomic Profiling by LC-HR-MS/MS
【24h】

Guidelines for Selection of Internal Standard-Based Normalization Strategies in Untargeted Lipidomic Profiling by LC-HR-MS/MS

机译:通过LC-HR-MS / MS选择基于内部标准的标准化策略的基于标准标准化策略的指导方针

获取原文
获取原文并翻译 | 示例
           

摘要

Due to variation in instrument response caused by various sources of errors throughout an analytical assay, data normalization plays an indispensable role in untargeted LC-MS profiling, yet limited accepted guidelines on this topic exist. In this work, a systematic comparison of several normalization techniques, mainly focusing on internal standard-based approaches, has been performed to derive some general recommendations. For generation of untargeted lipidomic data, a comprehensive ultra-high performance liquid chromatography (UHPLC)-electrospray ionization (ESI)-quadrupole time of flight (QTOF)-MS/MS method was utilized. To monitor instrument stability and evaluate normalization performance, quality control (QC) samples, prepared from aliquots of all experimental samples, were embedded in the sequence. Stable isotope labeled standards, representing differing lipid classes, were spiked to each sample as internal standards for postacquisition normalization. Various metrics were used to compare distinct normalization strategies, with reduction of variation in QC samples being the critical requirement for acceptance of successful normalization. The comparison of intragroup coefficients of variation (CVs), median absolute deviations (MADs), and variance enables simple selection of the best performance of normalization with improved and coherent results. Furthermore, the importance for normalization in critical data sets, showing only minor effects between groups with high variation and outliers, is pointed out. Apart from normalization, also, influences of used raw data types are demonstrated. In addition, effects of various factors throughout the processing workflow were investigated and optimized. Eventually, implementation of quality control samples, even if not required for normalization, provided a useful basis for assessing data quality. Due to lack of consensus for selecting optimum normalization, suggestions for validating data integrity are given.
机译:由于在分析测定中由各种误差源引起的仪器响应的变化,数据标准化在未确定的LC-MS分析中起着不可或缺的作用,但存在有限的接受指南。在这项工作中,已经进行了系统比较了几种正常化技术,主要关注基于内部标准的方法,以获得一些一般性建议。对于产生未明确的脂质组数据,利用了一种综合的超高效液相色谱(UHPLC) - Electrospray电离(ESI)-Quadrupole飞行时间(QTOF)-MS / MS方法。为了监测仪器稳定性和评估归一化性能,质量控制(QC)样品从所有实验样品中的等分试样制备,嵌入序列中。标记标准的稳定同位素标准标准,其掺入每个样品作为后续标准化的内部标准。使用各种指标来比较明显的归一化策略,减少QC样本的变化是接受成功正常化的关键要求。变异内部(CVS),中位绝对偏差(MADS)和差异的比较使得能够简单选择具有改进和连贯的结果的最佳归一化性能。此外,指出了关键数据集中标准化的重要性,仅指出具有高变化和异常值的组之间的次要效果。除了归一化之外,还证明了所使用的原料数据类型的影响。此外,还研究了各种因素的影响,并进行了优化。最终,即使不是规范化所必需的,也为评估数据质量提供了有用的基础,即使不需要进行质量控制样本。由于选择最佳标准化缺乏共识,给出了验证数据完整性的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号