Molecular weight distribution (MWD) is often the most informative analytical parameter in polymer analysis, with gel permeation chromatography (GPC) being the most common approach for determining the MWD for polymer samples. Many industrially relevant polymers lack chromogenic or fluorogenic signatures, precluding use of spectroscopy-based detection. Universal detectors, such as evaporative light scattering and charged aerosol detectors, are nonlinear, limiting quantitative polymer analysis. Differential refractive index (dRI) detectors show linear mass concentration sensitivity but are limited for some analyses given that they are incompatible with gradient-based separations, have a limited dynamic range, and require extended thermal equilibration times. In this study, we investigated the utility of silicon photonic microring resonator arrays as a quantitative mass concentration detector for industrial polymer analysis. Microring resonators have optical properties that are sensitive to changes in refractive index, offer an extended dynamic range, have a broad solvent compatibility, and have a linear mass concentration detection for a range of molecular weights. Linear mass concentration detection for microrings was demonstrated through a series of isocratic GPC separations using narrow MWD polystyrene (PS) standards. This detection technology was then utilized in conjunction with conventional GPC detectors to analyze a series of broad MWD PS standards, with results in good agreement with dRI and UV/visible. These results demonstrate the potential of the microring resonator platform as a detector for industrial polymer analysis.
机译:分子量分布(MWD)通常是聚合物分析中最具信息的分析参数,凝胶渗透色谱(GPC)是用于确定聚合物样品的MWD的最常见方法。许多工业相关的聚合物缺乏发色性或荧光差异,妨碍使用基于光谱的检测。诸如蒸发光散射和带电气溶胶探测器的通用探测器是非线性的,限制定量聚合物分析。差分折射率(DRI)探测器显示线性质量浓度灵敏度,但有限于给定的一些分析,因为它们与基于梯度的分离不兼容,具有有限的动态范围,并且需要延长的热平衡时间。在本研究中,我们研究了硅光子微管谐振器阵列的效用作为用于工业聚合物分析的定量质量浓度检测器。微管谐振器具有对折射率变化敏感的光学性质,提供延长的动态范围,具有广泛的溶剂相容性,并且具有线性质量浓度检测,用于一系列分子量。通过使用窄MWD聚苯乙烯(PS)标准的一系列等级GPC分离来证明微瘤的线性质量浓度检测。然后与传统的GPC探测器一起使用该检测技术以分析一系列广泛的MWD PS标准,结果与DRI和UV /可见的良好一致。这些结果证明了微耦合谐振器平台作为工业聚合物分析的检测器的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号