首页> 外文期刊>BioMed research international >Feasibility Study of Automated Framework for Estimating Lung Tumor Locations for Target-Based Patient Positioning in Stereotactic Body Radiotherapy
【24h】

Feasibility Study of Automated Framework for Estimating Lung Tumor Locations for Target-Based Patient Positioning in Stereotactic Body Radiotherapy

机译:抗肺肿瘤位置自动化框架的可行性研究,对靶向患者定位定位术术患者放射疗法

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. To investigate the feasibility of an automated framework for estimating the lung tumor locations for tumor-based patient positioning with megavolt-cone-beam computed tomography (MV-CBCT) during stereotactic body radiotherapy (SBRT). Methods. A lung screening phantom and ten lung cancer cases with solid lung tumors, who were treated with SBRT, were employed to this study. The locations of tumors in MV-CBCT images were estimated using a tumor-template matching technique between a tumor template and the MV-CBCT. Tumor templates were produced by cropping the gross tumor volume (GTV) regions, which were enhanced by a Sobel filter or a blob structure enhancement (BSE) filter. Reference tumor locations (grand truth) were determined based on a consensus between a radiation oncologist and a medical physicist. Results. According to the results of the phantom study, the average Euclidean distances of the location errors in the original, Sobel-filtered, and BSE-filtered images were 2.0 ± 4.1mm, 12.8 ± 9.4 mm, and 0.4 ± 0.5 mm, respectively. For clinical cases, these were 3.4 ± 7.1mm, 7.2 ± 11.6 mm, and 1.6 ± 1.2 mm, respectively. Conclusion. The feasibility study suggests that our proposed framework based on the BSE filter may be a useful tool for tumor-based patient positioning in SBRT.
机译:客观的。探讨自动框架估算肿瘤患者肺肿瘤位置的自动框架与立体定向体放射治疗(SBRT)估算肿瘤患者定位的可行性。方法。用SBRT治疗的肺部筛选幽灵映射和十个肺癌病例,用于本研究。使用肿瘤模板和MV-CBCT之间的肿瘤模板匹配技术估计MV-CBCT图像中肿瘤的位置。通过种植粗糙肿瘤体积(GTV)区域产生肿瘤模板,这些区域由Sobel过滤器或BloB结构增强(BSE)过滤器增强。基于放射肿瘤科医生和医学物理学家之间的共识来确定参考肿瘤位置(盛大真理)。结果。根据Phantom研究的结果,原始,Sobel过滤和BSE滤波图像中的位置误差的平均欧几里德距离分别为2.0±4.1mm,12.8±9.4 mm,分别为0.4±0.5毫米。对于临床案例,这些分别为3.4±7.1mm,7.2±11.6毫米,分别为1.6±1.2 mm。结论。该可行性研究表明,我们基于BSE滤波器的提出框架可以是SBRT中基于肿瘤患者定位的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号