...
首页> 外文期刊>American Journal of Veterinary Research >Noninvasive measurements of body composition and body water via quantitative magnetic resonance, deuterium water, and dual-energy x-ray absorptiometry in awake and sedated dogs
【24h】

Noninvasive measurements of body composition and body water via quantitative magnetic resonance, deuterium water, and dual-energy x-ray absorptiometry in awake and sedated dogs

机译:通过定量磁共振,氘水和双能X射线吸收法对清醒和镇静狗进行身体成分和身体水的无创测量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective-To compare quantitative magnetic resonance (QMR), dual-energy x-ray absorptiometry (DXA), and deuterium oxide (D2O) methods for measurement of total body water (TBW), lean body mass (LBM), and fat mass (FM) in healthy dogs and to assess QMR accuracy. Animals-58 Beagles (9 months to 11.5 years old). Procedures-QMR scans were performed on awake dogs. A D2O tracer was administered (100 mg/kg, PO) immediately before dogs were sedated, which was followed by a second QMR or DXA scan. Jugular blood samples were collected before and 120 minutes after D2O administration. Results-TBW, LBM, and FM determined via QMR were not significantly different between awake or sedated dogs, and means differed by only 2.0%, 2.2%, and 4.3%, respectively. Compared with results for D2O dilution, QMR significantly underestimated TBW (10.2%), LBM (13.4%), and FM (15.4%). Similarly, DXA underestimated LBM (7.3%) and FM (8.4%). A significant relationship was detected between FM measured via D2O dilution and QMR (r(2) > 0.89) or DXA (r(2) > 0.88). Even though means of TBW and LBM differed significantly between D2O dilution and QMR Or DXA, values were highly related (r(2) > 0.92). Conclusions and Clinical Relevance-QMR was useful for determining body composition in dogs and can be used to safely and rapidly acquire accurate data without the need for sedation or anesthesia. These benefits can facilitate frequent scans, particularly in geriatric, extremely young, or ill pets. Compared with the D2O dilution method, QMR correction equations provided accurate assessment over a range of body compositions. (Am J Vet Res 2013;74:733-743)
机译:目的-比较定量磁共振(QMR),双能X射线吸收法(DXA)和二氧化氘(D2O)方法测量人体总水(TBW),瘦体重(LBM)和脂肪质量的方法( FM),以评估QMR的准确性。 Animals-58 Beagles(9个月至11.5岁)。对清醒的狗进行程序-QMR扫描。在给狗镇静之前,立即使用D2O示踪剂(100 mg / kg,PO),然后进行第二次QMR或DXA扫描。在施用D2O之前和之后120分钟收集颈静脉血样。通过QMR测定的结果,清醒或镇静犬的TBW,LBM和FM差异不显着,均值分别仅相差2.0%,2.2%和4.3%。与D2O稀释的结果相比,QMR大大低估了TBW(10.2%),LBM(13.4%)和FM(15.4%)。同样,DXA低估了LBM(7.3%)和FM(8.4%)。通过D2O稀释测量的FM与QMR(r(2)> 0.89)或DXA(r(2)> 0.88)之间检测到显着关系。即使D2O稀释和QMR或DXA之间的TBW和LBM均值存在显着差异,其值仍高度相关(r(2)> 0.92)。结论与临床相关性QMR可用于确定犬的身体成分,可用于安全,快速地获取准确的数据,而无需镇静或麻醉。这些好处可以促进频繁的扫描,特别是在老年,极年轻或生病的宠物中。与D2O稀释法相比,QMR校正方程式可对一系列人体成分进行准确评估。 (Am J Vet Res 2013; 74:733-743)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号