Objective-To measure respiratory motion of the thoracic wall region in dogs using a real-time motion tracking system and compare the amount of respiratory motion between dogs positioned with and without a vacuum-formable cushion. Animals-8 healthy adult mixed-breed dogs (median weight, 23 kg). Procedures-Dogs were anesthetized and positioned in sternal and dorsal recumbency with and without a vacuum-formable cushion. Three-dimensional movement of anatomic landmarks was measured with a real-time motion capture system that tracked the locations of infrared light emitting diodes attached externally to the dorsal or ventral and lateral aspects of the thoracic wall. Results-Dogs positioned in sternal recumbency had significantly less cranial-to-caudal and left-to-right respiratory motion at the lateral aspect of the thoracic wall, compared with dogs positioned in dorsal recumbency, whether or not a cushion was used. For dogs treated in sternal recumbency, use of a cushion significantly increased the peak displacement vector (overall movement in 3-D space) for 3 of 4 marker locations on the dorsal thoracic wall. As respiratory rate increased, respiratory motion at the lateral and ventral aspects of the thoracic wall decreased when data for all dogs in dorsal recumbency were evaluated together. Conclusions and Clinical Relevance-Associations between respiratory rate and respiratory motion suggested that the use of rapid, shallow ventilation may be beneficial for dogs undergoing highly conformal radiation treatment. These results provide a basis for further research on respiratory motion in anesthetized dogs. (Am J Vet Res 2013;74:11-16)
机译:目的-使用实时运动跟踪系统测量狗胸壁区域的呼吸运动,并比较有无真空垫的狗之间的呼吸运动量。动物:八只健康的成年混血狗(体重中位数23公斤)。程序-狗麻醉和胸骨和背卧位有和没有真空可形成的垫子。使用实时运动捕获系统测量了解剖标志的三维运动,该系统跟踪了红外发光二极管的位置,该红外发光二极管外部附着在胸壁的背侧或腹侧和外侧。结果:与背侧卧位的狗相比,无论是否使用垫子,位于胸骨卧位的狗与位于背侧卧位的狗相比,在胸壁外侧的头到尾和从左到右的呼吸运动明显更少。对于以胸骨下垂治疗的狗,使用缓冲垫可显着增加背侧胸壁上4个标记位置中3个的峰值位移矢量(3-D空间中的整体运动)。随着呼吸频率的增加,当一起评估所有背卧位狗的数据时,胸壁的侧面和腹侧的呼吸运动会减少。结论和临床相关性-呼吸频率与呼吸运动之间的关联表明,快速,浅通气的使用可能对接受高度保形放射治疗的狗有益。这些结果为进一步研究麻醉犬的呼吸运动提供了基础。 (Am J Vet Res 2013; 74:11-16)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号