首页> 外文期刊>農業機械學刊 >THE FEEDBACK CONTROL SYSTEM OF THE ACTIVATED SLUDGE PROCESS FOR SWINE WASTEWATER TREATMENT
【24h】

THE FEEDBACK CONTROL SYSTEM OF THE ACTIVATED SLUDGE PROCESS FOR SWINE WASTEWATER TREATMENT

机译:猪废水处理活性污泥工艺的反馈控制系统

获取原文
获取原文并翻译 | 示例
           

摘要

In the intensively extended three-stage swine wastewater treatment system by agriculture authority in Taiwan, the activated sludge process is the most difficult stage for pig farmers to operate. The main purpose of this study is to develop an automatic control system to help farmers operating this process and thus improving the effluent quality. In the developed control system, a single mixed liquor suspended solids (MLSS) sensor and a personal computer were used for data processing, while maintaining the MLSS of the aeration tank at a suitable level by sludge recycling was adopted as the control strategy. The results showed that, when system operating at influent BOD of 1,500-5,000 mg/L, a volumetric loading of 0.41 g BOD/L/d and an F/M ratio of 0.17 kg BOD/kg MLSS/d, 95% and 99% of BOD and SS removal efficiencies were achieved, respectively. Also, the tolerable shock loading for this system was 35% compared with the designated set point. Therefore, it could be concluded both the automation and improvement of the treatment efficiency were successfully achieved for this system.
机译:在台湾农业管理局集中扩展的三级猪污水处理系统中,激活的污泥过程是猪农民运作的最困难的阶段。本研究的主要目的是开发一种自动控制系统,帮助农民运行该过程,从而提高污水质量。在开发的控制系统中,使用单个混合的液体悬浮固体(MLS)传感器和个人计算机进行数据处理,同时通过污泥回收保持在合适水平的曝气罐的MLSS作为控制策略。结果表明,当系统在1,500-5,000mg / L的流入BOL处运行时,0.41g BOD / L / D的体积负载和0.17kg BOD / kg MLS / D,95%和99的F / m比。分别实现了BOD和SS去除效率的百分比。此外,与指定的设定点相比,该系统的可容忍冲击载荷为35%。因此,可以得出结论,对该系统成功实现了治疗效率的自动化和改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号