Background Scapholunate instability (SLI) is the most common form of carpal instability. Early detection of SLI is imperative as early reconstructive procedures can potentially prevent the natural history of progressive degenerative arthritis. After wrist arthroscopy, magnetic resonance imaging (MRI) remains the next best noninvasive diagnostic option; however, access still remains costly and is often limited in many health care systems worldwide. In this article, we describe a novel device that allows for dynamic X-rays to be taken, accentuating the scapholunate (SL) widening. Description of Technique Twist X-ray views are generated by the patient clenching a device that combines the standard clenched fist views with ulnar deviation and supination. The test is easy to perform and functions by combining a higher grip force with the ulnar deviation and pronation effects of the extensor carpi ulnaris tendon, thus accentuating the SL gap in dynamic instability. Patients and Methods We present a series of four patients with dynamic SLI and compare the findings of the Twist X-rays with conventional wrist X-rays series, including standard anteroposterior, lateral, radial, and ulna deviation, clenched fist, and pencil grip views. Results In all the four patients, there was substantial dynamic SL widening. The SL interval increased from a mean of 1.8 mm (range: 1.5–2.8) on posteroanterior X-rays to 6.3 mm (range: 4.6–8.2) with the Twist views. Interestingly, on the pencil grip view, the mean widening was only 1.5 mm (range: 1–2.8 mm). Conclusion The authors describe a novel device that allows for improved detection of dynamic SL ligament instability when performing stress X-ray views of the wrist. Level of Evidence This is a Level IV study.
机译:背景技术Scapholunate不稳定性(SLI)是最常见的腕骨不稳定形式。早期检测SLI是必要的,因为早期重建程序可能会阻止进步性退行性关节炎的自然历史。在腕部关节镜检查之后,磁共振成像(MRI)仍然是下一个最佳的非侵入性诊断选择;然而,访问仍然保持昂贵,并且在全球许多医疗保健系统中往往有限。在本文中,我们描述了一种新颖的装置,其允许采取动态X射线,诱惑扫描素(SL)加宽。技术描述扭曲X射线视图由钳位握紧装置,该装置将标准夹紧的拳头视图与尺尺寸偏差结合起来。通过将较高的抓握力与伸肌偏离肌腱的尺寸偏差和校验效果相结合,可以易于执行和起作用,从而在动态不稳定性中突出SL间隙。患者和方法我们提出了一系列动态SLI的四个患者,并将扭曲X射线的调查结果与传统的腕X射线系列进行了比较,包括标准前后,横向,径向和尺骨偏差,握紧拳头和铅笔握住视图。结果所有四名患者,有大量动态的SL扩大。 SL间隔从后肌X射线上的1.8 mm(范围:1.5-2.8)的平均值增加到6.3毫米(范围:4.6-8.2),扭曲视图。有趣的是,在铅笔抓地面上,平均扩展仅为1.5毫米(范围:1-2.8毫米)。结论作者描述了一种新颖的装置,其允许在执行手腕的应力X射线视图时改善动态SL韧带不稳定性的检测。证据水平这是IV一级研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号