摘要

The two adsorptive stripping voltammetric approaches for detection and quantitative determination of diethyl (2E)-2-{(2E)-[1-(4-methylphenyl)imidazolidin-2-ylidene]hydrazinylidene}butanedioate (DIB)-a novel molecule of medical importance-using two sensitive sensors based on modified glassy carbon electrodes as reusable sensors, were developed for the first time. The proposed electrochemical methods are based on adsorptive/reductive behaviour of DIB at two modified carbonic electrodes: a bismuth film-modified glassy carbon electrode (BiF/GCE) and a lead film-modified glassy carbon electrode (PbF/GCE). The electron gain mechanism for the electrochemical reduction of DIB on both developed sensors was proposed for the first time. To achieve the highest sensitivity in adsorptive stripping determinations, various experimental variables (e.g. the composition and pH of the supporting electrolytes, deposition conditions of bismuth and lead films, concentrations of plating solutions, accumulation times and potentials of DIB, etc.) were extensively examined. The comparison of validation parameters obtained during the determination of DIB at two sensors was presented. The excellent linear correlation was found between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 15-600 mu g L-1 at an accumulation time of 30 s (with LOD = 4.2 mu g L-1 and LOQ = 14.0 mu g L-1) using the BiF/GCE as a sensor. Furthermore, the excellent linear relationship was confirmed between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 9-900 mu g L-1 at an accumulation time of 10 s (with better LOD = 1.5 mu g L-1 and LOQ = 5.0 mu g L-1), employing the PbF/GCE as a sensor. The two optimized adsorptive stripping voltammetric approaches-as facile, sensitive, reliable and inexpensive-were successfully used as first methods for the quantitative analysis of a novel anticancer agent (DIB) in its pure pharmaceutically acceptable form. However, the practical applicability of square-wave adsorptive stripping voltammetric determination of the electroactive DIB molecule at a PbF/GCE, as the modified electrode of higher sensitivity, was presented after its successful solid phase extraction from a real serum sample.
机译:用于检测和定量测定二乙基(2E)-2 - (2E) - [1-(4-甲基苯基)咪唑唑烷-2- ylidene]肼肼肼(DIB)-A新型医学分子的检测和定量测定的两种吸附剥离伏安法使用基于改性玻璃电极的两个敏感传感器作为可重复使用传感器的重要性,首次开发。所提出的电化学方法基于DIB在两个改性碳电极的吸附/还原行为:铋膜改性玻璃电极(BIF / GCE)和铅膜改性玻璃电极(PBF / GCE)。第一次提出了两个发达传感器上DIB电化学减少的电子增益机制。为了在吸附剥离测定中获得最高的敏感性,广泛地检查了各种实验变量(例如,铋和铅膜的支撑电解质的组合物和pH,铋和铅膜的沉积条件,浓度的镀液溶液,累积时间和电位等) 。提出了在两个传感器确定DIB期间获得的验证参数的比较。在30 s的累积时间下,在监测的吸附剥离伏安峰值电流和15-600μmg l-1的浓度范围内的Dib浓度在30 s的累积时间(带=4.2μgl-1和loq =之间,发现优异的线性相关性14.0 mu g l-1)使用BIF / GCE作为传感器。此外,在10 s的累积时间下,在9-900μmg l-1的范围内确认优异的线性关系在9-900 mu g l-1的范围内(具有更好的LOD =1.5μgl-1和LOQ = 5.0 mu g l-1),采用PBF / GCE作为传感器。两种优化的吸附剥离伏安方法 - 作为容易性,敏感,可靠且廉价的方法,被成功用作以纯的药学上可接受的形式定量分析新型抗癌剂(DIB)的方法。然而,在从真正的血清样品中成功的固相提取后,提出了在PBF / GCE处以PBF / GCE的改性电极在PBF / GCE下的实际适用性,作为更高灵敏度的改性电极。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号