Use of a Continuous Stirred Tank Reactor for the Determination of Electrospray Response Factors and Its Application to Underivatized Sugars Under Various Solvent Parameters

机译:使用连续的搅拌釜反应器用于在各种溶剂参数下测定电喷雾响应因子及其在劣化的糖中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

The relationship between the electrospray ionization (ESI)-mass spectrometric (MS) response of an analyte and its concentration has been well studied for permanently charged and basic analytes in the positive ionization mode, but there has been a lack of research effort for other analytes, and for the negative ionization mode, in general. In this study, this relationship was investigated for various adducts and deprotonated species of glucose, sucrose, and raffinose using a continuous stirred tank reactor (CSTR) coupled with ESI-tandem MS to obtain a continuum of response factors across a wide concentration range in both the positive and negative ionization modes with a single injection under 18 different combinations of solvents and additives. Profiles of response factors vs. concentrations varied widely and were dependent upon the analyte and solvent parameters. The use of ammonium trifluoroacetate resulted in the highest response factors for methanol-based and acetonitrile-based solvents in the positive and negative ionization modes, respectively. Ammonium acetate, ammonium formate, and sodium chloride in 80:20 acetonitrile:water in the negative ionization mode resulted in good linearities, useful for quantitative analysis. In the positive ionization mode, response factors tended to increase with an increase in the molecular weight of the analyte, and acetonitrile was generally found to decrease response factors. We have also demonstrated the ability of CSTR-ESI-MS to visualize ionization suppression in the presence of co-analytes. These data should be useful for liquid chromatography-ESI-MS method development for sugar analysis, to help guide the choice of mobile phase that will result in high sensitivity and linearity.
机译:用于分析物的电喷雾电离(ESI) - 谱图(MS)响应的关系,并对阳性电离模式的永久充电和基本分析物进行了很好地研究了对其存在的基本分析物,但对其他分析物缺乏研究努力以及一般来说,对于负电离模式。在这项研究中,使用连续搅拌釜反应器(CSTR)对各种加合物,蔗糖和棉子糖的各种加合物和质子化物种进行研究,以与ESI串联MS相结合,以在两者中获得广泛浓度范围的响应因子的连续因子在18个不同组合的溶剂和添加剂组合下单一注射的正极和负电离模式。响应因子与浓度的谱不同广泛变化,依赖于分析物和溶剂参数。三氟乙酸铵的使用分别导致甲醇基和乙腈基溶剂的最高响应因子分别在正极和负电离模式中。乙酸铵,甲酸铵和氯化钠在80:20乙腈:负电离模式中的水导致良好的线性,可用于定量分析。在阳性电离模式中,通常发现响应因子随着分析物的分子量的增加而增加,并发现乙腈减少响应因子。我们还表明CSTR-ESI-MS在共分析物存在下可视化电离抑制的能力。这些数据对于液相色谱-SI-MS方法开发应该是糖分析的方法,帮助指导将导致高灵敏度和线性度的流动阶段的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号