Biomechanical comparison of three different plate configurations for comminuted clavicle midshaft fracture fixation

机译:粉碎锁骨骨干骨折固定三种不同板配置的生物力学比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Background The aim of this study was to compare the fixation rigidity of anterior, anterosuperior, and superior plates in the treatment of comminuted midshaft clavicle fractures. Methods Six-hole titanium alloy plates were produced according to anatomic features of fourth-generation artificial clavicle models for anterior (group I; n?=?14), anterosuperior (group II; n?=?14), and superior (group III; n?=?14) fixation. After plate fixation, 5-mm segments were resected from the middle third of each clavicle to create comminuted fracture models. Half the models from each group were tested under rotational forces; the other half were tested under 3-point bending forces. Failure modes, stiffness values, and failure loads were recorded. Results All models fractured at the level of the distalmost screw during the failure torque, whereas several failure modes were observed in 3-point bending tests. The mean stiffness values of groups I to III were 636?±?78, 767?±?72, and 745?±?214 N ? mm/deg ( P ?=?.171), respectively, for the torsional tests and 38?±?5, 20?±?3, and 13?±?2 N/mm, respectively, for the bending tests ( P ? P ?=?.015 for group II vs. group III). The mean failure torque values of groups I to III were 8248?±?2325, 12,638?±?1749, and 10,643?±?1838 N ? mm ( P ?=?.02 for group I vs. II), respectively, and the mean failure loads were 409?±?81, 360?±?122, and 271?±?87 N, respectively ( P ?=?.108). Conclusions In the surgical treatment of comminuted midshaft clavicle fractures, the fixation strength of anterosuperior plating was greater than that of anterior plating under rotational forces and similar to that of superior plating.
机译:背景技术本研究的目的是比较前部,绕线和高板的固定刚度在处理粉碎的胎轴锁骨骨折中。方法采用六孔钛合金板材根据前期的第四代人工锁骨模型的解剖学特征(组I; N?= 14),Anterosuior(II组; N?=?14)和优越的(III组; n?=?14)固定。在夹层固定后,从每个锁骨的中间三分之一的中间分解5mm的区段以产生粉碎的骨折模型。从旋转力下测试来自每组的一半模型;另一半在3点弯曲力下测试。记录失败模式,刚度值和故障载荷。结果所有型号在故障扭矩期间最远端螺钉的水平裂缝,而在3点弯曲试验中观察到几种故障模式。 I至III族的平均刚度值为636?±78,767?±72和745?±214 n?分别为扭转试验和38?±5,20?±3分别用于弯曲试验的mm / deg(p?= 171)分别用于弯曲试验(p? p?= ~~~~~~~第三组的第II族。 I至III组的平均故障扭矩值为8248?±2325,12,638?±1749和10,643?±1838 n? mm(p?=Δ.02对于II族),分别平均故障载荷为409?±81,360?±122和271?±87n,分别(p?=? .108)。结论在粉碎胎轴锁骨骨折的外科治疗中,翼形电镀的固定强度大于旋转力下的前镀层的固定强度,类似于优质电镀。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号