BackgroundIn search of new possibilities in 3D surface imaging, several nonmedical scanning systems have been assessed for their implementation in plastic surgery. The aim of this study was to compare a new affordable 3D imaging consumer product with an established medical 3D imaging system for objective 3D breast imaging. MethodWe compared a low-cost mobile, handheld scanner against an established medical 3D surface imaging system. Forty-two female patients who underwent different types of breast surgery were captured in a 3D view with both devices. Digital breast measurement, volume measurement, and breast surface-to-surface analysis were done using Mirror software. Repeatability was assessed by repeated 3D scans of the torso and surface-to-surface analysis. ResultsDigital breast measurement showed low differences with good-to-excellent correlation between both devices. Mean breast volume difference was small (?5.11?±?32.10?mL) within the 95% limits of agreement. Surface-to-surface analysis yielded a higher surface deviation in the lower breast quadrants (1.62?±?0.80 mm root mean square [RMS] error and 1.81?±?0.88 mm RMS error) than in the upper breast quadrants. Repeatability was satisfactory with a mean of 0.636?±?0.279 mm RMS error. ConclusionAffordable mobile surface scanners may offer new perspectives in the future for 3D breast imaging. Although surface acquisition was sufficient for breast measurements in comparison to an established system, the lack of appropriate medical software for patient consultation next to moderate texture quality needs to be improved for wider acceptance in plastic surgery.
机译:背景搜索3D表面成像中的新可能性,已经评估了它们在整形外科的实施中的几种非医疗扫描系统。本研究的目的是将新的经济实惠的3D成像消费者与具有目标3D乳房成像的建立的医学3D成像系统进行比较。方法我们比较了一个低成本的移动,手持扫描仪对既定的医疗3D表面成像系统。在与两个设备的3D视图中捕获了在接受不同类型的乳房手术的42例女性患者。使用镜像软件完成数字乳房测量,体积测量和乳房表面对表面分析。通过重复的躯干和表面到表面分析评估重复性。结果Digital乳房测量显示出低差异,两种器件之间的相关性良好。在协议的95%限制范围内,平均乳房体积差异小(?5.11?±32.10毫秒)。表面到表面分析产生较低乳房象限的表面偏差(1.62?±0.80 mm根均方[rms]误差和1.81?±0.88 mm rms误差)比上部乳房象限。重复性令人满意,平均值为0.636?±0.279 mm rms误差。结案,移动表面扫描仪可能会在未来提供新的视角,用于3D乳房成像。虽然与建立的系统相比,表面采集足以进行乳房测量,但缺乏适当的医疗软件,以遵循适度质地质量的患者咨询,以便更广泛接受整形手术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号