Comprehensive Comparison of Axial Length Measurement With Three Swept-Source OCT-Based Biometers and Partial Coherence Interferometry.

机译:三个扫掠源10型生物夹的轴向长度测量综合比较和部分相干干涉测量。

获取原文
获取原文并翻译 | 示例

摘要

To compare axial length measurements (and failure rate) of three swept-source optical coherence tomography (SS-OCT)-based biometers: IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany), OA-2000 (Tomey, Nagoya, Japan), and Argos (Movu Inc., Komaki, Japan) to those provided by a partial coherence interferometry (PCI)-based optical biometer (IOLMaster v5.4 [Carl Zeiss Meditec]). A total of 119 patients (171 eyes) undergoing cataract surgery were enrolled. Axial length was measured with the four biometers in a random order. Chi-square analysis was used to determine whether statistically significant differences in success rates were found between biometers. Within-subject standard deviation (S_(w)), test-retest repeatability (TRT), coefficient of variation (CoV), and intraclass correlation coefficients (ICCs) were calculated to analyze the intraobserver repeatability. Bland-Altman plots were used for agreement assessment. Axial length measurements were successfully measured in 166 eyes (97.08%) with the IOLMaster 700, 166 eyes (97.08%) with the OA-2000, 170 eyes (99.42%) with the Argos, and 138 eyes (80.70%) with the IOLMaster v5.4. Chi-square analysis indicated a significant difference in the failure rate between PCI- and SS-OCT-based biometers (P < .001). Intraobserver repeatability for the IOLMaster 700, OA-2000, and Argos showed excellent repeatability with low TRT (0.03, 0.06, and 0.05 mm, respectively), low CoV (0.04%, 0.10%, 0.07%, respectively), and high ICC (1.000, 0.999, and 1.000, respectively). The Bland-Altman 95% limits of agreement were as narrow as 0.09 mm, indicating excellent agreement among the three SS-OCT biometers and the PCI biometer. The three SS-OCT biometers showed a significantly higher success rate for axial length measurement than the IOLMaster v5.4 in various lens opacities. These SS-OCT biometers are likely to become the gold standard for axial measurement. [J Refract Surg. 2019;35(2):115-120.].
机译:比较三个扫描源光学相干断层扫描(SS-OCT)的生物扫描(SS-OCT)的轴向长度测量(和故障率):IOLMASTER 700(Carl Zeiss Meditec,Jena,德国),OA-2000(Tomey,Nagoya,Japan),和Argos(Movu Inc.,Komaki,Japan)通过部分相干干涉测量(PCI)的光学生物计(Iolmaster V5.4 [Carl Zeiss Meditec])提供的那些。共有119名患者(171只眼)进行白内障手术。以随机顺序用四个生物夹测量轴向长度。 Chi-Square分析用于确定生物夹之间是否发现了成功率的统计学上显着差异。在主题内标准偏差(S_(W)),测试 - 测试重复性(TRT),变形系数(COV)和跨读性相关系数(ICC)以分析intraObserver重复性。 Bland-Altman Plots用于协议评估。轴向长度测量以166只眼(97.08%)成功测量,随着OA-2000,170,170只眼(99.42%),用Argos和138只眼(80.70%),138只眼(80.70%)。 v5.4。 Chi-Square分析表明了基于SS-OCT的生物磁点之间的故障率(P <.001)之间的故障率显着差异。 IOLMASTER 700,OA-2000和ARGOS的垄断重复性显示出具有低TRT(0.03,0.06和0.05mm)的优异的重复性,低COV(0.04%,0.10%,0.07%)和高ICC( 1.000,0.999和1.000分别)。 Bland-Altman 95%的协议限额为0.09毫米,表明三个SS-OCT生物磁点和PCI生物计之间的良好协议。三个SS-OCT生物座位显示出比各种透镜不透明度的IOLMASTER V5.4的轴向长度测量的成功率明显更高。这些SS-OCT生物座位可能成为轴向测量的金标准。 [j屈服surg。 2019; 35(2):115-120。]。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号