PURPOSE: To study the effect of acid etching and the application of a hydrophobic bonding resin on the microtensile bond strengths (microTBS) and marginal sealing of the 1-step self-etch adhesive Adper Easy Bond (AEB). METHODS: Middle dentin was exposed in 30 extracted molars and randomly divided into six groups: (1) AEB applied as per manufacturer's directions; (2) as in AEB, but one coat of hydrophobic resin (HR) was applied and cured over AEB (AEB+HR); (3) etching with 35% H3PO4 for 15 seconds followed by AEB (Etch+AEB); (4) as in group Etch+AEB, but one coat of HR was applied and cured over AEB (Etch+AEB+HR); (5) Adper Single Bond Plus, the 2-step etch-&-rinse adhesive control (ASB); (6) Adper Scotchbond Multi-Purpose, the 3-step etch-&-rinse adhesive control (SBMP). Buildups were constructed with Filtek Z250 and cured in three increments of 2 mm each. Specimens were sectioned with a slow-speed diamond saw under water in X and Y directions to obtain bonded sticks with a cross section of 0.8 +/- 0.2 mm2 and tested to failure in tension mode at a crosshead speed of 1 mm/minute. Statistical analyses were computed using one-way ANOVA followed by Duncan's post-hoc test at P<0.05. For marginal sealing, 36 Class V preparations were restored with one of the six adhesive combinations and processed with 50% ammoniacal silver nitrate. After sectioning, specimens were observed under a backscattered FE-SEM to evaluate silver infiltration into the resin-dentin interface, which was measured in ranks (0-4) and compared with non-parametric statistical tests (P<0.05). RESULTS: AEB resulted in statistically lower mean microTBS than all other groups at P0.05. All the remaining groups resulted in statistically similar mean microTBS. For marginal sealing, data were grouped in three statistical subsets: Groups AEB and AEB+HR resulted in statistically less silver infiltration than groups Etch+AEB and Etch+AEB+HR. Groups ASB and SBMP resulted in similar silver infiltration compared to Groups AEB and AEB+HR. The nanoleakage pattern consisted of agglomerates of silver deposits located predominantly in the hybrid layer, while reticular or water-tree silver deposits were observed in both the AEB and ASB adhesive layers.
机译:目的:研究酸腐蚀和疏水性粘结树脂对微拉伸粘结强度(microTBS)和一步法自腐蚀粘结剂Adper Easy Bond(AEB)的边缘密封的影响。方法:将中层牙本质暴露在30颗磨牙中,随机分为6组:(1)按照制造商的指示进行AEB; (2)与AEB相同,但在AEB上涂覆一层疏水性树脂(HR)并固化(AEB + HR); (3)用35%H3PO4蚀刻15秒,然后进行AEB(蚀刻+ AEB); (4)与Etch + AEB组一样,但在AEB上涂上一层HR并固化(Etch + AEB + HR); (5)Adper Single Bond Plus,两步蚀刻和冲洗粘合控制(ASB); (6)Adper Scotchbond Multi-Purpose,3步蚀刻和冲洗粘合控制(SBMP)。用Filtek Z250构建堆积物,并以三个增量(每次2 mm)固化。用慢速金刚石锯在水中在X和Y方向上对样品进行切片,以获得横截面为0.8 +/- 0.2mm 2的粘合棒,并以1mm /分钟的十字头速度在拉伸模式下进行测试。使用单向方差分析和邓肯事后检验以P <0.05进行统计分析。对于边缘密封,用六种粘合剂组合之一修复了36种V类制剂,并用50%氨水硝酸银进行了处理。切片后,在反向散射FE-SEM下观察样品,以评估银渗透到树脂-牙本质界面中的程度(等级0-4),并与非参数统计测试进行比较(P <0.05)。结果:在0.05时,AEB的平均平均microTBS低于所有其他组。其余所有组均产生统计学上相似的平均microTBS。对于边缘密封,将数据分组为三个统计子集:AEB组和AEB + HR组比Etch + AEB组和Etch + AEB + HR组产生的银渗透率统计较低。与AEB和AEB + HR组相比,ASB和SBMP组导致类似的银渗透。纳米泄漏模式由主要位于杂化层中的银沉积物的附聚物组成,而在AEB和ASB粘合剂层中均观察到网状或水树状的银沉积物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号