Effects of Scanning Strategy and Scanner Type on the Accuracy of Intraoral Scans: A New Approach for Assessing the Accuracy of Scanned Data

机译:扫描策略与扫描仪类型对跨内扫描准确性的影响:一种评估扫描数据准确性的新方法

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose This study aimed to determine the most reliable scanning strategy and scanner type, using a new protocol for assessing the accuracy (trueness and precision) of intraoral scan data. Materials and Methods Five different maxillary and mandibular typodont pairs (n = 10) and 2 intraoral scanners were used for the study. A reference scan for each arch was obtained with an industrial scanner. Scanning strategies were classified into 2 continuous methods-continuous scan in horizontal direction (CH group) and continuous scan with vertical rotation in anterior region (CV group)-and 1 segmental method (S group). In the CH group, the scanner head was maintained mostly in a horizontal position. In the CV group, the scanners were rotated 180 degrees around the anterior tooth region to allow smooth scanning through the area. The intraoral scan data were individually superimposed over their corresponding reference scan data. Raw data of the distances between paired surface points were extracted from the superimposed pairs of datasets, with (original distance values) or without consideration (absolute distance values) of the value signs. Trueness values were calculated using absolute distance values, while precision values were obtained from original distance values. Data were analyzed with a 2-way repeated-measures analysis of variance using alpha = 0.05 as the level of significance. Results The CV group produced significantly inferior outcomes compared to the CH and S groups in terms of trueness (p< 0.001, F = 24.67), whereas no significant differences were observed among the 3 scanning strategies with respect to precision (p= 0.451, F = 0.83). Scanner type did not produce significant differences in terms of either trueness (p= 0.058, F = 4.72) or precision (p= 0.742, F = 0.12). Conclusions The segmental approach for scanning the region of interest first and continuous scanning with the scanner head held mostly in a horizontal position are both acceptable as full-arch scanning strategies. However, vertical rotation of intraoral scanners should be minimized.
机译:目的本研究旨在使用新协议来确定最可靠的扫描策略和扫描仪类型,用于评估脑内扫描数据的准确性(真实和精度)。材料和方法五种不同的上颌和下颌岩型对(n = 10)和2个口腔扫描仪用于研究。使用工业扫描仪获得每个拱的参考扫描。扫描策略分为2个连续方法 - 在水平方向(CH组)中连续扫描,并在前部区域(CV组)中具有垂直旋转的连续扫描 - 以及1个分段方法(S组)。在CH组中,扫描仪头部大部分保持在水平位置。在CV组中,扫描仪在前齿区域周围旋转180度,以允许通过该区域平滑扫描。在其相应的参考扫描数据上单独叠加内部扫描数据。成对表面点之间的距离的原始数据从叠加的数据集中提取(原始距离值)或不考虑值标志的(绝对距离值)。使用绝对距离值计算真实值,而从原始距离值获得精度值。通过双向重复措施的分析分析数据,使用α0.05作为显着性水平的差异分析。结果CV组在真实方面与CH和S组相比产生了显着劣等的结果(P <0.001,F = 24.67),而3扫描策略在精度方面没有显着差异(P = 0.451,F. = 0.83)。扫描仪类型在真实的方面没有产生显着差异(P = 0.058,F = 4.72)或精度(P = 0.742,F = 0.12)。结论使用主要处于水平位置的扫描仪头部的扫描区域的扫描区域的分段方法是全拱扫描策略的扫描仪头部。然而,应最小化口腔扫描仪的垂直旋转。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号