...
首页> 外文期刊>Journal of prosthodontics: official journal of the American College of Prosthodontists >Volumetric Evaluation of Void/Gap Formation and Microleakage Cementing Fiber Posts on Extracted Teeth with Three Different Cements
【24h】

Volumetric Evaluation of Void/Gap Formation and Microleakage Cementing Fiber Posts on Extracted Teeth with Three Different Cements

机译:空隙/间隙形成和微透噪声粘合纤维柱的体积评估,用三种不同的水泥提取牙齿

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose To evaluate microleakage in roots restored with fiber posts cemented using three different luting cements, to measure the volume of voids/gaps within the obturated/postcemented root canals, and to examine whether microleakage and the volume of voids/gaps were correlated. Materials and Methods Thirty-six extracted human mandibular incisors were decoronated, and the root canals were obturated using gutta-percha and sealer in the experimental groups (n = 30). Six roots were used as controls. A standard post space was prepared, and an identically sized fiber post was cemented in each experimental specimen using one of three luting cements (Panavia F2.0, Bifix SE, GC FujiCEM; n = 10 each). The specimens were scanned using micro-computed tomography, and the volume of voids/gaps was determined. The specimens were then subjected to a fluid filtration assay to evaluate microleakage. Results The volume of voids/gaps was significantly lower in the GC FujiCEM group, and significantly less microleakage occurred in the Bifix SE group compared with other groups (both p 0.001). A significant correlation between the volume of voids/gaps and leakage was found only in the Panavia F2.0 group (p = 0.003; r = 0.830). No such correlation was found in the analysis of all groups combined. Conclusions The group with the greatest volume of voids/gaps (Bifix SE) showed the least microleakage, and the group with the smallest volume of voids/gaps (GC FujiCEM) showed the most microleakage. Panavia F2.0 ranked between and exhibited significant correlation.
机译:目的在用三种不同的戒断水泥巩固的纤维柱恢复的根中恢复的纤维柱,以测量封闭式/突出的根管内的空隙/间隙体积,并检查微漏和空隙/间隙的体积是否相关。材料和方法提取了三十六种提取的人颌骨牙髓,并且在实验组中使用Gutta-Percha和密封剂封闭根系管(n = 30)。六根根用作对照。制备了标准的柱子空间,并且使用三种Luting PENCED之一(Panavia F2.0,Bifix Se,GC Fujicem; N = 10)中的每种实验标本中巩固相同的纤维柱。使用微计算断层扫描扫描样品,测定空隙/间隙的体积。然后将样本进行流体过滤测定以评估微渗透。结果GC Fujicem组的空隙/间隙的体积显着降低,与其他基团相比,Bifix Se组中发生显着较低的微渗透物(P <0.001)。仅在Panavia F2.0组中发现空隙/间隙和泄漏体积之间的显着相关性(P = 0.003; r = 0.830)。在分析所有组合的分析中没有发现这种相关性。结论具有最大的空隙/间隙(BIFIX SE)的组均显示出最小的微透盖,并且具有最小体积的空隙/间隙(GC FUJICEM)的组显示出最多的微透盖。巴伐利亚F2.0排名在一起并表现出显着的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号