首页> 外文期刊>Journal of Pharmacological and Toxicological Methods >Simultaneous measurement of arterial and left ventricular pressure in conscious freely moving rats by telemetry
【24h】

Simultaneous measurement of arterial and left ventricular pressure in conscious freely moving rats by telemetry

机译:通过遥测自由移动大鼠动脉和左心室压力的同时测量

获取原文
获取原文并翻译 | 示例
       

摘要

Comprehensive cardiovascular assessment in conscious rodents by utilizing telemetry has been limited by the restriction of current devices to one pressure channel. The purpose of this study was to test and validate a dual pressure transmitter that allows the simultaneous measurement of arterial pressure (AP) and left ventricular pressure (LVP) in conscious freely moving rats. Six rats were surgically implanted with dual pressure transmitters. Baseline hemodynamics and circadian rhythm were observed to return within 7 days. AP, heart rate (HR), LVP and indices of left ventricular contractility were stable and demonstrated a prominent circadian rhythm over a two-week period of uninterrupted recordings. Administration of the vasodilator nifedipine produced the anticipated dose-dependent decrease in AP which was accompanied by a baroreflex mediated increase in HR and cardiac contractility. The negative inotrope verapamil produced the expected dose-dependent decreases in AP and cardiac contractility. Finally, a terminal validation of the dual pressure transmitter was performed under anesthesia by measuring AP and LVP simultaneously via telemetry and from a fluid filled arterial catheter and an intraventricular Millar catheter, respectively. A range of pressures and cardiac contractility were studied by administering sequential intravenous infusions of the positive inotrope dobutamine followed by verapamil. Linear regression analysis revealed a high level of agreement between pressures measured by the dual pressure transmitter and the exteriorized catheters. Histopathologic analysis of the heart revealed mild peri-catheter fibrosis. In conclusion, the simultaneous measurement of AP and LVP offers the potential for more detailed cardiovascular assessment in conscious rats. (C) 2016 Elsevier Inc. All rights reserved.
机译:通过利用遥测的有意识啮齿动物的综合心血管评估受到电流设备到一个压力通道的限制。本研究的目的是测试和验证双压力变送器,允许在有意识的自由移动大鼠中同时测量动脉压(AP)和左心室压(LVP)。用双压力发射器手术植入六只大鼠。观察到基线血流动力学和昼夜节律在7天内返回。左心室收缩性的AP,心率(HR),LVP和索引稳定,并在两周的不间断记录期间展示了突出的昼夜节律。血管扩张剂的施用产生预期的剂量依赖性降低的AP,其伴随着胚胎介导的HR和心脏收缩性的增加。阴性肌肤静脉酰胺在AP和心脏收缩性中产生预期的剂量依赖性降低。最后,通过遥测和流体填充的动脉导管和腔内Millar导管同时测量AP和LVP,在麻醉下进行双重压力变送器的终端验证。通过施用阳性Inotrope Dobutamine的连续静脉内输注,然后进行维拉帕米,研究了一系列压力和心脏收缩性。线性回归分析显示通过双压力发射器和外部化导管测量的压力之间的高度协议。心脏的组织病理学分析显示出轻度静脉纤维化。总之,AP和LVP的同时测量为有意识的大鼠提供更详细的心血管评估的可能性。 (c)2016年Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号