首页> 外文期刊>Journal of nuclear medicine technology >The Effect of an Asymmetric Energy Window on Bone Scintigraphy Image Quality
【24h】

The Effect of an Asymmetric Energy Window on Bone Scintigraphy Image Quality

机译:非对称能量窗口对骨闪烁图像质量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Bone scintigraphy is one of the most common nuclear medicine tests. Previous work investigated the effectiveness of an asymmetric window (ASW) for planar bone scintigraphy using simulation and phantom data. Phantom studies concluded that the ASW improved both the resolution and the contrast-to-noise ratio when imaging objects with high scatter. The aim of this study was to confirm this improvement increased image quality in patients. This study also investigated whether the differences between a symmetric window (SW) and an ASW depended on body mass index. Methods: Fifty-eight patients had 2 scans: a standard scan using an SW of 140 keV ± 10% and a scan using an ASW of 140 keV + 10% and - 7.5%. Three readers independently compared the 2 image sets and scored them using a 5-score scale (ranging from 1 = ASW better [clinically important] to 5 = SW better [clinically important]). Scores from all radiologists were pooled and analyzed statistically. A P value of less than 0.05 was considered statistically significant. Results: In 93 cases (53%), the readers scored the ASW images better than the SW images. In 5 cases (3%), the ASW images were preferred, with the difference considered clinically important; there were no cases in which the SW was similarly preferred. For the sign test, we determined whether the total of 93 scores of 1 or 2 (ASW preferred) was significantly different from the 15 scores of 4 or 5 (SW preferred). The P value was less than 0.00001, demonstrating that the difference was significant. Conclusion: In patients undergoing bone scintigraphy, ASW provided an improvement in image quality that in some cases was judged clinically important.
机译:骨闪烁图是最常见的核医学试验之一。以前的工作研究了使用模拟和幻像数据的平面骨闪烁图的非对称窗口(ASW)的有效性。幻影研究得出结论,ASW在具有高散射的对象时改善了分辨率和对比度噪声比。本研究的目的是确认这种改善提高了患者的图像质量。本研究还研究了对称窗口(SW)和ASW之间的差异依赖于体重指数。方法:58名患者有2个扫描:标准扫描使用140keV±10%的SW,使用140 keV + 10%和-7.5%的扫描。三个读者独立地比较了2个图像集并使用5分刻度进行评分(从1 = ASW更好地[临床上重要]到5 = SW更好[临床上重要])。所有放射科医生的分数被统计和分析。 P值小于0.05被认为是统计学意义的。结果:93例(53%),读者比SW图像更好地划分ASW图像。在5例(3%)中,ASW图像是优选的,差异被认为是临床重要的重要性;没有类似地优选SW的病例。对于标志测试,我们确定了1或2(ASW优选)的总共93分(ASW优选)与4或5分(SW优选)的总和显着不同。 P值小于0.00001,表明差异很大。结论:在接受骨闪烁的患者中,ASW提供了改善图像质量,即在某些情况下临床重要意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号