首页> 外文期刊>Journal of Performance of Constructed Facilities >In Situ Lateral Load Testing of a Two-Story Solid Clay Brick Masonry Building
【24h】

In Situ Lateral Load Testing of a Two-Story Solid Clay Brick Masonry Building

机译:原位横向载荷测试两层固体粘土砖砌砖砌体大厦

获取原文
获取原文并翻译 | 示例
           

摘要

The seismic behavior of unreinforced masonry (URM) structures has usually been investigated by conducting laboratory tests. Such efforts, although useful in order to understand the response of single walls or subassemblages, cannot fully mimic the in situ seismic response of masonry buildings. In this study, in situ lateral load testing of a two-story full-scale URM building was conducted. First, forced vibration tests were performed to determine the vibration frequencies of the building. Afterwards, the building was tested by reacting against a braced steel frame built behind the test building and imposing one-way cyclic displacements. The building was pushed until 20% loss of lateral load capacity, which corresponds to a drift ratio of approximately 0.8%. The diagonal tension cracking of the walls was followed by sliding of the second-story concrete slab over the walls. A three-dimensional nonlinear finite-element analysis of the test building was conducted to simulate the behavior of the test building. The results showed that upon careful selection of the contact cohesion at the slab-wall interfaces, the numerical model provided reasonable estimations of the global structural behavior in terms of load-deformation response.
机译:通常通过进行实验室测试来研究未原始的砌体(URM)结构的地震行为。这种努力虽然有用,以了解单墙或子组件的响应,但不能完全模仿砌体建筑的原位地震反应。在这项研究中,在本研究中,进行了两层全尺寸URM建筑的横向载荷测试。首先,进行强制振动测试以确定建筑物的振动频率。之后,通过对测试建筑后面的支撑钢框架反应并施加单向循环位移来测试建筑物。推动该建筑直至横向载荷能力损失20%,其对应于约0.8%的漂移比。墙壁的对角线张力裂缝之后是在壁上滑动第二层混凝土板滑动。进行了测试建筑的三维非线性有限元分析以模拟测试建筑的行为。结果表明,在仔细选择平板壁界面处的接触内聚力时,在负载变形响应方面提供了合理的全局结构行为的合理估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号