...
首页> 外文期刊>Journal of pediatric orthopaedics. Part B >Correction of complex lower limb angular deformities with or without length discrepancy in children using the TL-HEX hexapod system: comparison of clinical and radiographical results
【24h】

Correction of complex lower limb angular deformities with or without length discrepancy in children using the TL-HEX hexapod system: comparison of clinical and radiographical results

机译:使用TL-Hex Hexapod系统在儿童中有或没有长度差异的复杂下肢角度畸形的校正:临床和射线照相结果的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to compare clinical and radiographical results for treatment of lower limb multiaxial deformities +/- limb length discrepancy (LLD) of at least 2 cm with the Truelok hexapod fixator system (TL-HEX). All consecutive cases of lower limb multiaxial deformities were included. Patients were divided in two groups: group 1, lower limb angular deformity+LLD less than 2 cm, and group 2, lower limb angular deformity+LLD of at least 2 cm. Only patients with age younger than or equal to 20 years and follow-up of 6 months after removal of the external fixator were included. A total of 27 (six femur and 39 tibia treated) and 20 patients (12 femur and 19 tibia) were enrolled in groups 1 and 2, respectively. Complete correction of the deformity was achieved in 90 and 96% of the patients in groups 1 and 2, respectively. There were no differences in terms of external fixator, maturation, and distraction indexes between the two groups and between different anatomical sites. Good to excellent functional results (ASAMI score) were obtained in 93% of patients in group 1 and 75% in group 2 (P=0.01). Complication rate was similar between the two groups (7.4 vs. 10%, respectively). Average follow-up after removal of the external fixator was 25.6 (range: 7.0-54.0) months. The TL-HEX external fixator system allows a predictable correction of complex lower limb deformities regardless of the presence of LLD. Although complication rate is similar between the two groups, lower functional outcomes can be expected in patients with significant preoperative LLD.
机译:本研究的目的是将临床和放射线照相结果进行比较,以处理至少2cm的下肢多轴畸形+/-肢体长度差异(LLD)与Truelok Hexapod固定器系统(TL-Hex)进行至少2cm。包括较低肢体多轴畸形的所有连续情况。患者分为两组:第1组,下肢角畸形+ LLD小于2cm,第2组,下肢角畸形+ LLD至少2厘米。仅包括年龄小于或等于20年的患者,并在除去外固定器后6个月的后续患者。共有27个(六只股骨和39名胫骨)和20名患者(12名股骨和19名胫骨)分别纳入第1组和2组。完全校正畸形分别在第1和第2组中的90%和96%的患者中实现。在两组和不同解剖部位之间的外部固定器,成熟和分心指标方面没有差异。良好的功能结果(ASAMI评分)是在第1族患者的93%和2组患者中获得的(P = 0.01)。两组之间并发症率相似(分别为7.4与10%)。移除外固定器后的平均随访25.6(范围:7.0-54.0)个月。 TL-HEX外部固定器系统允许可预测的校正复杂的下肢畸形,无论LLD的存在如何。虽然两组之间并发症率类似,但在具有重要术前LLD的患者中可以预期较低的功能结果。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号