Objective To present a three-dimensional (3D)-printed model that simulates endoscopic and exoscopic intracerebral hematoma (ICH) surgery with a tubular retractor. Methods We used 3D printing technology to develop the model that consisted of the skull frame and a replaceable inserted module. Edible gelatin and animal blood were placed into the module to mimic brain tissue and the hematoma. Twenty neurosurgeons were recruited to participate in our training program that required the use of an endoscope and an exoscope to aspirate the hematoma with a tubular retractor. Five postgraduates were asked to complete the entire training with the endoscope five times. Questionnaires were distributed for feedback after the training program. Results The more experienced surgeons obviously performed better than the rather inexperienced surgeons, verifying that our model could reflect the ability of the trainees. As the training progressed, the scores of the postgraduates increased, and the average score of the fifth training was obviously higher than the first score. No significant differences were observed in the trainees' performance with the endoscope and the exoscope. The feedback questionnaires showed the average score for value of the simulator as a training tool was a 3.65 (on a 4-point scale). Our model received better comments regarding the bone texture (mean: 3.20), the brain tissue texture (mean: 3.20), and the experience in aspirating the hematoma (mean: 3.10). The surgical position (mean: 2.95), surgical approach (mean: 2.90), and simulated brain tissue (mean: 2.85) should be improved. Conclusion Our model was practical for endoscopic and exoscopic ICH surgery training. The results of our program showed that prior surgical experience benefited the mastery of both the endoscopic and the exoscopic ICH surgery in the 3D-printed model. Our model could make mastering basic skills more efficient.
机译:目的介绍一种用管状牵开器模拟内窥镜和倾斜脑血肿(ICH)手术的三维(3D)。方法采用3D打印技术开发由骷髅框架和可更换插入模块组成的模型。将可食用的明胶和动物血液置于模块中以模拟脑组织和血肿。招募了二十个神经外科医生参加我们的培训计划,要求使用内窥镜和一个外腔,以用管状牵开器吸出血肿。要求五次使用内窥镜完成整个研究生五次。问卷在培训计划后分发了反馈。结果越多的外科医生明显表现优于相当缺乏经验的外科医生,验证我们的模型可以反映受训人员的能力。随着培训进展,研究生的分数增加,第五次培训的平均得分明显高于第一次得分。在具有内窥镜和外部镜的学员的性能下没有观察到显着差异。反馈问卷显示模拟器值的平均分数,因为培训工具是3.65(在4分)上)。我们的模型对骨骼纹理(平均值:3.20),脑组织纹理(平均值:3.20)以及吸入血肿的经验(平均值:3.10)。外科手术位置(平均:2.95),手术方法(平均值:2.90)和模拟脑组织(平均:2.85)应得到改善。结论我们的模型对于内窥镜和倾向的手术训练是实用的。我们的计划结果表明,先前的手术经验使掌握了3D印刷模型中的内窥镜和抗诊断手术。我们的模型可以使掌握基本技能更有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号