首页> 外文期刊>Journal of occupational and environmental hygiene >Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators
【24h】

Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators

机译:用于呼吸器配合性呼吸器的呼吸器配合能力测试的推荐测试方法和通过/失败标准

获取原文
获取原文并翻译 | 示例
           

摘要

This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount (R) Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit.
机译:本研究评估了用于开发半掩模空气净化颗粒呼吸器的呼吸器配合能力(RFC)测试的关键测试参数和通过/失效标准选择。 使用25个主题测试面板,收集了基准RFC数据,为101个国家职业安全和健康认证的呼吸器模型。 这些模型进一步分为61个,双或三尺寸的家庭。 使用N95-Companion附件和职业安全和健康管理可接受的定量拟合测试方案,使用Portacount(R)加上完成拟合测试。 进行每项受试者/呼吸器模型组合的三次重复测试(Donnings)。 对于每个模型,使用五种不同的替代标准来确定面板通过率(PPR)(25-主题面板的数量或达到可接受拟合的百分比),以确定可接受的拟合。