The paper presents two methods to grow the LiF single crystal impurified with Mg and Ti, used to manufacture the TL detectors in the form of chips, in IFIN-HH. The comparative analysis of the methods have shown that the chips obtained by Czochralschi (Cz) method have a homogeneity that corresponds to the parameters required by the standards in force, IEC 1066 - Thermoluminescence Dosimetry System for Personal and Environmental Monitoring, 1991, for a much larger number of detectors in a lot (as e.g. the detectors obtained by Bridgman method), and, consequently, they can be used in personnel dosimetry. LiF: Mg, Ti, Tl detectors (chips) are aimed to measure the echivalent absorbed dose in the range of 5 o 10'5 - 10 Sv, generated by ionizing radiation having the energy between 15 keV and 3 MeV. The document also presents the parameters and characteristics of the detectors produced in IFIN-HH, irradiated and tested with a 60Co source (A = 3 Ci), l37Cs (A = 30 mCi) and at the 7 MeV electron linear accelerator in NILPRP.
机译:本文呈现了两种方法,将生长用Mg和Ti杂化的生长单晶,用于以芯片的形式制造IFIN-HH的TL探测器。该方法的比较分析表明,Czochralschi(CZ)方法获得的芯片具有均匀性,其对应于备线标准,IEC 1066 - 热致发光剂量剂量系统,​​用于个人和环境监测,1991年的均匀性较多的探测器(例如通过Bridgman方法获得的检测器),因此它们可以用于人员剂量测定法。 LiF:Mg,Ti,TL探测器(芯片)旨在测量通过电离辐射产生的5℃10'5-10sv的抵抗的吸收剂量,其能量在15keV和3mev之间产生。该文献还介绍了IFIN-HH中产生的检测器的参数和特性,用60Co源(A = 3 CI),L37CS(A = 30MCI)和NILPRP中的7MEV电子线性加速器进行辐照和测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号