首页> 外文期刊>Journal of minimally invasive gynecology >Evaluation of Positioning Devices for Optimization of Outcomes in Laparoscopic and Robotic-Assisted Gynecologic Surgery
【24h】

Evaluation of Positioning Devices for Optimization of Outcomes in Laparoscopic and Robotic-Assisted Gynecologic Surgery

机译:腹腔镜和机器人辅助妇科手术优化定位装置的定位装置

获取原文
获取原文并翻译 | 示例
       

摘要

In this review, we evaluate techniques, devices, and equipment for patient positioning and their effect on patient outcomes, such as cephalad slide and neuropathy, in laparoscopic and robotic-assisted gynecologic surgery. We conducted a systematic review by searching MEDLINE, Embase, and Cochrane Library for relevant articles published over a 15-year period. Study selection, data extraction, and quality assessment were performed by 2 reviewers independently. Seven articles, including 3 randomized controlled trials and 4 case series, were included in our analysis. Four studies evaluated cephalad patient slide. In 2 randomized controlled trials (n = 103), the mean slide with various devices (i.e., memory foam, bean bag with shoulder braces, egg crate, and gel pad) ranged from 1.07 +/- 1.93 cm to 4.5 +/- 4.0 cm. The use of a bean bag with shoulder supports/braces was associated with minimal slide, with a median slide of 0 cm (range, 0-2 cm) in a retrospective series and with mean slide of 1.07 +/- 1.93 cm in a randomized controlled trial (vs memory foam). No conclusive effect of body mass index on slide could be identified. Five studies evaluating the incidence of neuropathy found an overall incidence of 0.16% and no differences among slide-preventing devices. The minimal slide described across studies supports the conclusion that any of the currently used devices and techniques for safe patient positioning are within reason. The low overall incidence of neuropathy is also reassuring. Best evidence recommendations cannot be made for a specific device or technique; our findings suggest the importance of strict adherence to the basic tenets of safe patient positioning to minimize slide and prevent nerve injury. (c) 2018 AAGL. All rights reserved.
机译:在本文中,我们评估患者定位的技术,装置和设备及其对腹腔镜和机器人辅助妇科手术中的患者结果的影响及其对患者结果的影响。我们通过在15年期间出版的相关文章搜索Medline,Embase和Cochrane图书馆进行系统审查。学习选择,数据提取和质量评估由2名审稿人独立执行。在我们的分析中包含七篇文章,其中包括3项随机对照试验和4个案例系列。四项研究评估了Cephalad患者幻灯片。在2个随机对照试验(n = 103)中,平均滑动有各种装置(即记忆泡沫,带肩部括号,蛋箱和凝胶垫)的均值范围为1.07 +/- 1.93cm至4.5 +/- 4.0厘米。使用带肩部支撑/支架的豆袋与最小载玻片相关,中值载玻片,回顾性系列中的0厘米(范围0-2cm),平均载玻片在随机化中的1.07 +/- 1.93cm。受控试验(VS内存泡沫)。可以识别身体质量指数对幻灯片上的确凿效果。评估神经病变发病率的五项研究发现,总发生率为0.16%,防止装置之间没有差异。跨研究所述的最小载玻片支持结论,即任何当前使用的设备和安全患者定位的技术都在原因。神经病变的低总体发病率也在放心。最佳证据建议不能为特定的设备或技术进行;我们的研究结果表明,严格遵守安全患者定位的基本原则的重要性,以尽量减少幻灯片,防止神经损伤。 (c)2018 AAGL。版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号