首页> 外文期刊>Journal of Materials Chemistry, C. materials for optical and electronic devices >Triple signalling mode carbon dots-based biodegradable molecularly imprinted polymer as a multi-tasking visual sensor for rapid and 'on-site' monitoring of silver ions
【24h】

Triple signalling mode carbon dots-based biodegradable molecularly imprinted polymer as a multi-tasking visual sensor for rapid and 'on-site' monitoring of silver ions

机译:基于碳点的三重信号模式可生物降解的分子印迹聚合物作为用于快速和“现场”的多任务视觉传感器的银离子监测

获取原文
获取原文并翻译 | 示例
       

摘要

The present work describes the fabrication of a [ow-cost, simpLe, and highly selective analytical method based on the unique combination of fluorescent carbon dots (CDs) and molecularly imprinted polymers (MIPs) for sensitive visual detection of silver ions at trace levels in real sampLes in both outdoors and at-home. For the first time, fluorescein dye is used as a precursor for the preparation of CDs. The prepared CDs have Low toxicity, high stability, good quantum yield, and are free from the common problems (Low stability, weak fluorescence intensity, and fast photo-bleaching) of commercially available dyes. The CDs modified MIP (CD5@MIP) has been successfully applied in calligraphy and staining of 3-D crafted papers. In addition, the prepared CD5@MIP has demonstrated the triple-signalling mode trace-level detection of silver ions, in which a simpLe CD5@MIP solution was sufficient to monitor the presence of silver ions in real and compLex matrices with the naked eye, i.e. instrument-free analysis (detection Limit = 10.0 mu g L-1). The CD5@MIP modified filter-paper strips can be used for the very handy, safe, sensitive, semi-quantitative and rapid detection of silver ions (response time <10 seconds). The silver ions present in real and compLex sampLes (Like human blood, urine, wastewater, silver cream and poLymeta[Lic ore) are easily analyzed and visually monitored by the strip as well as the solution-phase CD5@MIP sensor. The prepared CD5@MIP shows negligible cytotoxicity towards MCF-7 cells, and has therefore been successfully explored for Live cell imaging and intracellular analysis of silver ions. The simple preparation, fast detection (<10 seconds), Low cost, easy-handling and Layman operation strategy demonstrate that the proposed sensor has potential as a practical and portable sensing interface for wide application in complex matrix analysis.
机译:本作者描述了基于荧光碳点(Cds)和分子印迹聚合物(MIPS)的独特组合的[OK成本,简单,高度选择性分析方法的制备,用于在痕量水平下对银离子进行敏感的视觉检测在户外和家庭中的真实样品。首次,荧光素染料用作制备Cds的前体。制备的CD具有低毒性,高稳定性,良好的量子产量,并且不含市售染料的常见问题(低稳定性,弱荧光强度和快速光漂白)。 CDS修改的MIP(CD5 @ MIP)已成功应用于书法和三维制作纸的染色。此外,制备的CD5 @ MIP已经证明了银离子的三态型模式痕量水平检测,其中简单的CD5 @ MIP溶液足以监测真实和复杂矩阵中的银离子的存在与肉眼,即无仪器分析(检测限=10.0μgl-1)。 CD5 @ MIP改性滤纸纸条可用于非常方便,安全,灵敏,半定量和快速检测银离子(响应时间<10秒)。实际和复杂样品中存在的银离子(如人血,尿液,废水,银霜和聚合物[LIC矿石),通过条带以及溶液相CD5 @ MIP传感器可视地分析和目视监测。制备的CD5 @ MIP显示出均可忽略的细胞毒性朝向MCF-7细胞,因此已成功探索过量细胞成像和银离子的细胞内分析。简单的准备,快速检测(<10秒),低成本,易于处理和外行操作策略表明,所提出的传感器具有用于广泛应用于复杂矩阵分析中的实用和便携式传感界面的潜能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号